SOLENOID VALVE DISASSEMBLY/ASSEMBLY (For Adfinity™ X20R)
Disassembly
1.
Lower the deck by pressing the pedal (11).
2.
Disconnect motor connectors, water line to deck at union (F) and two mounting screws holding deck to lift arms (G).
3.
Remove deck
4.
Remove the screw (A), disconnect the connector (B) and recover the gasket.
5.
Disconnect the union (C) from the solenoid valve (D) and recover the gasket.
6.
Remove the screws (E).
7.
Recover the solenoid valve (D).
Assembly
8.
Assemble the components in the reverse order of disassembly.
Adfinity™ 17ST / 20ST / X20R / 20D / X20D / X20C / X24D
SERVICE MANUAL
SOLUTION/CLEAN WATER SUPPLY SYSTEM
ENGLISH
23
9096982000