3. HOW TO SET UP THE EQUIPMENT
Motion sensor menu
Adjust these settings to view a clearer picture of the seabed, fish schools etc when in
moderate to rough seas.
Note 1: Your SMD12/SMD16 has an internal motion sensor. Motion sensor setup is
not required if [Fish Finder Source] in the [Sounder] menu is set to [Internal].
Note 2: To use the heaving function, the following settings are required at the satellite
compass. For the setting procedure, see the operator's manual for your satellite com-
pass. Settings for SC-30 are done from the [IF-NMEASC] menu, settings for SC-50/
110 are done from the [DATA OUT] menu.
Sentence
Baud rate
Cycle
PGN
When you tap [Transducer Setup] from the [Sounder] menu, the [Motion Sensor]
menu is shown beneath the [Transducer Setup] menu. If the satellite compass SC-30
or SC50/110 is connected, set the distance between the antenna unit (or sensor) of
the satellite compass and transducer (high and low if connected) here.
Menu item
[Motion Sensor
Select the sensor connected to your Multi-Function Dis-
Type]
play. For all sensors other than SC-50/110, select [SC-30].
[Antenna Posi-
Set the distance from the antenna unit to the transducer in
tion Bow/Stern
the bow-stern direction. If the transducer is located on the
HF (LF)]
fore side, set a positive value.
[Antenna Posi-
Set the distance from the transducer to the antenna unit in
tion Up/Down HF
the vertical direction.
(LF)]
[Antenna Port/
Set the distance from the antenna unit to the transducer in
Starboard HF
the port-starboard direction. If the transducer is located on
(LF)]
the starboard side, set a positive value.
3-32
ATT, HVE
38400BPS
25ms
SC-30/50/110
HF Transducer
HF Transducer
Up/Down
Up/Down
LF Transducer
LF Transducer
Description
NMEA0183
Heave: 65280
Attitude: 127257
Bow/Stern for HF
Bow/Stern for HF
Port/Starboard for HF
Port/Starboard for HF
Port/Starboard for LF
Port/Starboard for LF
Bow/Stern for LF
Bow/Stern for LF
CANbus
Options
(setting range)
[SC30],
[SC50_SC110]
[-99.9] to [+99.9]
[-0.00] to [+99.9]
[-99.9] to [+99.9]