Suzuki SMD12 Installation Manual page 59

Multi-function display
Hide thumbs Also See for SMD12:
Table of Contents

Advertisement

[Initial Setup] menu - [SC-30 SETUP]
This menu is only available with SC-30 connection.
Menu item
[WAAS Mode]
Select [ON] to use the WAAS mode.
[Heading Offset]
Enter the offset value for heading.
[Pitch Offset]
Enter the offset value for pitching.
[Roll Offset]
Enter the offset value for rolling.
[Initial Setup] menu - [NETWORK SENSOR SETUP]
The [NETWORK SENSOR SETUP] section allows you to set up compatible FURUNO
NMEA2000 sensors. Calibrations and offsets applied in this menu are also applied to
the sensor itself.
Tap the sensor to access its menus and settings. For details regarding the menu struc-
ture and set up of each sensor, see the appropriate operator's manual, supplied with
the sensor.
[Initial Setup] menu - [CALIBRATION]
Menu item
[Heading]
Offset heading data.
[Speed Through
Calibrate speed data. Enter amount in percentage.
Water]
[Wind Speed]
Offset wind speed data. Enter amount in percentage. -50% to +50%
[Wind Angle]
Offset wind angle data.
[Sea Surface
Offset sea surface temperature data.
Temperature]
[Initial Setup] menu - [DATA DAMPING]
Menu item
[COG & SOG]
[Heading]
[Speed Through Water]
[Wind Speed & Angle]
[Rate of Turn]
[Initial Setup] menu - [FUSION]
Menu item
[Connect to Fusion]
[Fusion Auto Volume]
[Minimum Speed]
[Maximum Speed]
[Volume Increase]
Description
Description
Description
Set data damping time. The lower the setting
the faster the response to change.
Description
Connects to your Fusion equipment.
Set to [ON] to allow the Multi-Function Dis-
play to control the FUSION volume. Volume
is adjusted according to vessel speed.
Set the minimum speed threshold. Exceed-
ing this speed activates volume auto control.
Set the maximum speed threshold.
Set the amount of extra volume to output
when the vessel reaches the [Maximum
Speed] setting.
3. HOW TO SET UP THE EQUIPMENT
Options (setting range)
[ON], [OFF]
-180° to +180°
-90° to +90°
-90° to +90°
Options (setting range)
-180.0° to +180.0°
-50% to +50%
-180° to +180°
-10°C to +10 °C
Options (setting range)
0 to 59 (seconds)
Options (setting range)
[ON], [OFF]
0.0 (kn) to 98.9 (kn)
0.1 (kn) to 99.0 (kn)
10% to 50%
3-21