Omron ZJ-SD Series User Manual page 64

Smart electrostatic sensor
Table of Contents

Advertisement

Section 4
Measuring Sheet Workpieces
Setting Tolerance Judgment Values
Refer to the HIGH threshold registered in step
(HIGH and LOW thresholds) for a PASS (OK) judgment.
The judgment result will be output based on the threshold value set here.
Output type = standard: "HIGH" "PASS" "LOW"
Output type = warning: "WARN" "OK" "NG"
Measurement result > HIGH threshold
LOW threshold ≤ Measurement result ≤ HIGH threshold
LOW threshold > Measurement result
|Measurement result| > warning level (*)
LOW threshold ≤ measurement result ≤ HIGH threshold
Measurement result > HIGH threshold
Or
LOW threshold > Measurement result
(*)The level is judged by absolute values as plus and minus warning levels exist.
Setting the Warning Level (Output type) p.82
Refer to "Section 5 DETAILED SETTINGS" for details on operation.
Inputting Threshold Values Directly p.65
ZJ-SD
50
User's Manual
Measurement result
and set the upper and lower limits
6
Judgment result
HIGH
PASS
LOW
WARN
OK
NG

Advertisement

Table of Contents
loading

Table of Contents