Omron ZJ-SD Series User Manual page 81

Smart electrostatic sensor
Table of Contents

Advertisement

Automatic Teaching
When automatic teaching is executed, measurement is performed continuously for the
duration that the keys are held down, and the minimum and maximum measurements
during that period are set as the threshold values.
Automatic teaching is useful when you want to set threshold values by actually starting
the device and obtaining real measurements.
Sensing object
Hold, trigger mode, and scaling settings that have been made before teaching are reflected in the
teaching measurements.
Moving to the T mode
1.
Set the mode switch to T.
2.
Start the device.
The threshold switch may be set to either position. Both HIGH and LOW thresholds are set,
regardless of the switch setting.
Maximum value =
HIGH threshold
Move
Sensing object
Section 5
Entering Threshold Values
Minimum value =
LOW threshold
User's Manual
ZJ-SD
67

Advertisement