Mounting on the Mounting Bracket

The following describes how to mount the laser type Smart Sensor (ZX-LD) and static
electricity sensor (ZJ-S), or ultrasonic type Smart Sensor (ZX-UD) and static electricity sensor
(ZJ-S) onto the exclusive mounting bracket (ZJ-XBU1).
Setting the Installation Distance p.41
■ Installation
Example of mounting the ZX-LD___
1.
Fix the ZX-LD___ onto the mounting bracket (ZJ-XBU1) using M3 screws.
The screws must be tightened with a torque of 0.3 Nm or less.
Take care not to touch the emitting/receiving section of the Sensor Head. Adhesion of finger marks may
prevent correct measurements. If you have touched them, wipe them with a clean, soft cloth.
2.
Fix the ZJ-S___ using the screws.
Do not allow anything to touch the metal case of the Sensor Head. Failure to do so might prevent accurate
measurement by the sensor.
Emitting/receiving
section
Sensing
section