4.2.1.4
Set Up Mode Error States
Table 4-4 describes the state of the indicators if errors occur at different
stages of the start-up process. For example, if the Micro-CS fails while
testing the hardware (state T2), the error condition is hardware failure
TE2. A description of each error condition follows Table 4-4.
Table 4-4 SETUP Mode Error Indicator States
Activity
TE2: Hardware failure
TE7: Booted wrong image
Key:
= On continuously
= Flashing regularly (about 1Hz)
Activity TE2: Hardware Failure
The ROM diagnostics detected a Micro-CS hardware problem requiring
service. Call technical support.
Activity TE7: Booted Wrong Image
The Micro-CS loaded an inappropriate image. Pressing the SETUP
switch approximately 3 seconds to generate a reset clears this error. The
Micro-CS loads inappropriate images if one of the following operator
errors occurs:
Configuring the Micro-CS with an incorrect file name or renaming or
copying the image file to the wrong name.
Supplying the wrong name to the boot command.
4.3

BOOT FAILURES

The procedures for troubleshooting a power-up failure established that
the hardware is functional
the Ethernet interface is functional
the Micro-CS can communicate with the Ethernet
If the Micro-CS still is not booted, you must pinpoint the problem. The
boot error report can help in this process.
Micro-CS Installation Guide