Table 4-2 Normal Mode Error Indicator States
Activity
NE2: Hardware failure
NE5: Booted wrong image
Key:
= On continuously
= Flashing regularly (about 1Hz)
Activity NE2: Hardware Failure
The ROM diagnostics detected a Micro-CS hardware problem requiring
service. Call technical support.
Activity NE5: Booted Wrong Image
The Micro-CS has just loaded an inappropriate image. Pressing the
SETUP switch for approximately 3 seconds to generate a reset clears this
error. The Micro-CS loads inappropriate images if one of the following
operator errors occur:
Configuring the Micro-CS with an incorrect file name or renaming or
copying the image file to the wrong name.
Supplying the wrong name to any of the boot commands (na boot,
dumpboot, or the superuser CLI boot).
If you are uncertain as to why the Micro-CS booted the wrong image,
enter Set Up mode and issue an image -d command. This command
shows which host file the Micro-CS is trying to load.

SETUP Mode

Pressing the SETUP switch within 3 seconds of either a reset or cycling
on power puts the Micro-CS into Set Up mode. The SETUP indicator is
on after pressing the SETUP switch.