UNIX Host on a SLIP Interface
When troubleshooting a UNIX host at the end of a SLIP network
interface, make sure
•
The host is booted and functioning properly.
•
The SLIP link is connected correctly.
•
The Internet addresses are correct for both sides of the SLIP link.
•
All Micro-CS software is installed properly on the host. See the
CSMIM2 Installation Notes.
•
The erpcd daemon or tftp server, which loads the operational image
to the Micro-CS, is running.
A PC host running the XENIX operating system has both the erpcd and
slipd daemons (provided with the distribution and installed in the file
/etc) running in the background on the PC. Set the Micro-CS and the
erpcd on the load host into Set Up mode:
•
For the Micro-CS, press SETUP following a reset and wait for the
monitor prompt.
•
For erpcd on the load server host, as superuser, kill the erpcd program
and restart it using the -D option:
# /etc/erpcd -D
Another Micro-CS
When troubleshooting a Micro-CS configured as a load server host
•
Use the CLI telnet command to access the unit and verify that it is up
and running.
•
Communicate with the unit on the Ethernet using the superuser CLI
ping command. Ping is also available through the monitor command.
•
Verify the unit's configuration using na or the admin command.
The CSMIM Network Administrator's Guide provides more information
on these commands.
Micro-CS Installation Guide
Load Server Host Not Responding
4-11