2.4

POWER-UP AND TEST

1.
Power up the MicroMMAC in accordance with the instruction found
in the MicroMMAC user documentation.
The Micro-CS now runs its ROM-resident power-up diagnostics. The
indicators momentarily light and then turn off, except for the NET
indicator.
2.
Verify that the CPU light on the MicroMMAC is blinking/green, and
that the LCD reads out correctly (refer to your MicroMMAC
documentation for information).
3.
Set the Micro-CS to ROM Monitor mode (SETUP and ATTN LEDs
on).
Press SETUP within 3 seconds of powering up to put the Micro-CS
into ROM Monitor mode. You can also reset the Micro-CS and enter
the ROM Monitor mode by pressing the SETUP switch for at least
three seconds, until the SETUP LED flashes indicating a reset.
Release the switch and all the port LEDs will turn on then off. Press
the SETUP switch again within 3 seconds after the PORT LEDs have
turned off, and the SETUP LED will be on indicating the Micro-CS is
in setup mode. Once the Micro-CS has successfully completed its
start-up diagnostics, the ATTN LED will turn on indicating ROM
Monitor mode.
Micro-CS Installation Guide
Maximum Recommended Cable Lengths
Feet
250
200
100
50
Power-up and Test
Cable Length
Meters
75
60
30
15
2-3