Carrier PIC 5+ User Manual page 68

Control for 19 series centrifugal chiller
Table of Contents

Advertisement

Table Name
PIC Table Type
PRSCAL04
Menu Name
Status
cal_en
0 to 1
1
2
cur_pres
3
cal_p1
4
cal_p2
5
cal_s
6
cal_i
7
cal_st
0 to 1
Table Name
PIC Table Type
PRSCAL05
Menu Name
Status
1
cal_en
0 to 1
cur_pres
2
3
cal_p1
4
cal_p2
5
cal_s
6
cal_i
7
cal_st
0 to 1
Table Name
PIC Table Type
PRSCAL06
Menu Name
Status
1
cal_en
0 to 1
2
cur_pres
cal_p1
3
4
cal_p2
5
cal_s
6
cal_i
7
cal_st
0 to 1
Table Name
PIC Table Type
VFD_OUT
Menu Name
Status
1
hdpv_out
0 to 22
2
vfd_out
0 to 100
3
vfdstart
0 to 1
tripr
0 to 1
4
5
ref_cool
0 to 1
6
fltreset
0 to 1
7
freezrel
0 to 1
8
read_cfg
0 to 1
Table Name
PIC Table Type
CFG_19DV
Menu Name
Status
1
mot_pol
0 to 1
2
3
gv2_lim
30 to 100
gv2_dmin
0 to 20
4
5
gv2_dful
10 to 100
6
gv2_dmax
90 to 120
7
gv2_d20
0.0~120.0
8
gv2_d30
0.0~120.0
9
gv2_d50
0.0~120.0
10
vfd_ratf
10 to 200
11
reg_tim
12
pgpumplm
68
Instance
HMI Menu Path
12H
22
//MAINMENU/MAINTAIN/
Default
Unit
Note Menu text description
0
-
0
PSIG
0
PSIG
0
PSIG
0
-
0
-
0
-
Instance
HMI Menu Path
12H
23
//MAINMENU/MAINTAIN/
Default
Unit
Note Menu text description
0
-
0
PSIG
0
PSIG
0
PSIG
0
-
0
-
0
-
Instance
HMI Menu Path
12H
24
//MAINMENU/MAINTAIN/
Default
Unit
Note Menu text description
0
-
0
PSIG
0
PSIG
0
PSIG
0
-
0
-
0
-
Instance
HMI Menu Path
13H
19
//MAINMENU/CONFIG/
Default
Unit
Note Menu text description
0
mA
0
%
0
-
0
-
0
-
0
-
0
-
0
-
Instance
HMI Menu Path
13H
20
//MAINMENU/CONFIG/
Default
Unit
Note Menu text description
0
-
-
96
%
2
-
90
-
94
-
28.1
-
37.2
-
71.6
-
80
Hz
120
min
600
min
Diff Press Calibration
Current Pressure
Calib Pres1(0 PSIG)
Calib Pres2(100-250PSIG)
Calibrated Slope
Calibrated Intercept
Calibration Completed
Oil Sump Press Cali
Current Pressure
Calib Pres1(0 PSIG)
Calib Pres2(100-250PSIG)
Calibrated Slope
Calibrated Intercept
Calibration Completed
Oil Supply Press Cali
Current Pressure
Calib Pres1(0 PSIG)
Calib Pres2(100-250PSIG)
Calibrated Slope
Calibrated Intercept
Calibration Completed
Head Pressure Reference
Target VFD Speed
VFD Start
Shunt Trip Relay
Refrigerant Cool Relay
VFD Fault Reset
Freeze Release
Read Configuration
Motor Pole Pair
Single=0, Double=1
IGV2 Travel Limit
IGV2 Minimum Degree
IGV2 Fully Open Degree
IGV2 Actuator Max Deg
IGV2 Deg @IGV1 20 Deg
IGV2 Deg @IGV1 30 Deg
IGV2 Deg @IGV1 50 Deg
VFD Rate Speed Hz
Purge Regen Lasting Time
Daily PG Pumpout Limit
Low
High
CCN
LEN
Limit
Limit
Force
Force
0
1
x
x
x
0
1
Low
High
CCN
LEN
Limit
Limit
Force
Force
0
1
x
x
x
0
1
Low
High
CCN
LEN
Limit
Limit
Force
Force
0
1
x
x
x
0
1
Low Limit
High Limit
0
22
0
100
0
1
0
1
0
1
0
1
0
1
0
1
Low
High
CCN
LEN
Limit
Limit
Force
Force
0
1
30
100
0
20
10
100
90
120
10
30
10
50
10
80
10
200