Carrier PIC 5+ User Manual page 66

Control for 19 series centrifugal chiller
Table of Contents

Advertisement

Table Name
PIC Table Type
MAIIOB
Menu Name
Status
vol_iob1
1
2
nm_peak1
3
low_vol1
0 to 1
4
fusstat1
0 to 1
5
vol_iob2
6
nm_peak2
7
low_vol2
0 to 1
8
fusstat2
0 to 1
9
vol_iob3
nm_peak3
10
11
low_vol3
0 to 1
12
fusstat3
0 to 1
13
vol_iob4
14
nm_peak4
15
low_vol4
0 to 1
16
fusstat4
0 to 1
17
vol_iob5
18
nm_peak5
low_vol5
0 to 1
19
20
fusstat5
0 to 1
21
vol_iob6
22
nm_peak6
23
low_vol6
0 to 1
24
fusstat6
0 to 1
Table Name
PIC Table Type
MAI_BDSN
Menu Name
Status
1
sn_iob1
2
sn_iob2
3
sn_iob3
4
sn_iob4
sn_iob5
5
6
sn_iob6
7
sn_siob
8
sn_ism
9
sn_gw
10
sn_dcib
11
svn_rev
Table Name
PIC Table Type
MAISWRST
Menu Name
Status
1
srd_shut
0.0 to 100.0
vfd_shut
0.0 to 100.0
2
3
gv1_shut
0.0 to 100.0
4
est_shut
-40 to 280
5
pd_dur
0 to 65535
6
power_dn
0 to 1
7
auto_rst
0 to 1
8
sw_rst
0 to 1
Table Name
PIC Table Type
MAIN_MS
Menu Name
Status
1
lead_lag
0 to 2
2
3
ms_ctrl
0 to 3
4
sl_ctrl
0 to 3
5
6
66
Instance
HMI Menu Path
12H
14
//MAINMENU/MAINTAIN/
Default
Unit
Note Menu text description
0
Volts
0
-
0
-
1
-
0
Volts
0
-
0
-
1
-
0
Volts
0
-
0
-
1
-
0
Volts
0
-
0
-
1
-
0
Volts
0
-
0
-
1
-
0
Volts
0
-
0
-
1
-
Instance
HMI Menu Path
12H
15
//MAINMENU/MAINTAIN/
Default
Unit
Note Menu text description
-
-
-
-
-
-
-
-
-
-
-
Instance
HMI Menu Path
12H
16
//MAINMENU/MAINTAIN/
Default
Unit
Note Menu text description
%
%
%
°F
0
min
0
-
0
-
0
-
Instance
HMI Menu Path
12H
17
//MAINMENU/MAINTAIN/
Default
Unit
Note Menu text description
-
-
-
-
-
-
IOB1 Power Supply Volt
IOB1 Num Peak Prev Sec
IOB1 Low Voltage Flag
IOB1 24VAC Fuse Status
IOB2 Power Supply Volt
IOB2 Num Peak Prev Sec
IOB2 Low Voltage Flag
IOB2 24VAC Fuse Status
IOB3 Power Supply Volt
IOB3 Num Peak Prev Sec
IOB3 Low Voltage Flag
IOB3 24VAC Fuse Status
IOB4 Power Supply Volt
IOB4 Num Peak Prev Sec
IOB4 Low Voltage Flag
IOB4 24VAC Fuse Status
IOB5 Power Supply Volt
IOB5 Num Peak Prev Sec
IOB5 Low Voltage Flag
IOB5 24VAC Fuse Status
IOB6 Power Supply Volt
IOB6 Num Peak Prev Sec
IOB6 Low Voltage Flag
IOB6 24VAC Fuse Status
IOB #1 Soft Part Number
IOB #2 Soft Part Number
IOB #3 Soft Part Number
IOB #4 Soft Part Number
IOB #5 Soft Part Number
IOB #6 Soft Part Number
SIOB Soft Part Number
ISM Software Part Number
Gateway Soft Part Number
DCIB Soft Part Number
MBB SVN Revision
SRD Position @Shutdown
VFD Speed @Shutdown
GV1 Position @Shutdown
Evap Sat Temp @Shutdown
Power Recovery Duration
Power Down Active
Auto Restart Active
Swift Restart Active
Unit is Lead or Lag
Disable=0, Lead=1, Lag=2
Master Control Type
Slave Control Type
Local=0, Network=1
Remote=2, Local Sched=3
Low
High
CCN
LEN
Limit
Limit
Force
Force
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Low
High
CCN
LEN
Limit
Limit
Force
Force
Low
High
CCN
LEN
Limit
Limit
Force
Force
0
100
0
100
0
100
-40
280
0
65535
0
1
0
1
0
1
Low
High
CCN
LEN
Limit
Limit
Force
Force
0
2
0
3
0
3