Carrier PIC 5+ User Manual page 65

Control for 19 series centrifugal chiller
Table of Contents

Advertisement

Table Name
PIC Table Type
MAIOTHER
Menu Name
Status
op_prest
no/yes
23
24
pump_srt
no/yes
25
pump_sht
no/yes
26
pump_rst
no/yes
27
ep_start
no/yes
28
ep_diag
no/yes
29
ep_freze
no/yes
30
ep_shut
no/yes
31
ep_pdown
no/yes
cp_prest
no/yes
32
33
cp_start
no/yes
34
cp_overr
no/yes
35
cp_shut
no/yes
36
cp_tower
no/yes
37
co_diag
no/yes
38
cp_freze
no/yes
39
cp_pdown
no/yes
40
cap_inhr
no/yes
cap_inhd
no/yes
41
42
cap_decd
no/yes
43
gv1_inhs
no/yes
44
cap_decs
no/yes
45
capinhst
no/yes
46
capdecst
no/yes
47
capinhcp
no/yes
48
capdeccp
no/yes
49
capinhmt
no/yes
50
capdecmt
no/yes
51
capinham
no/yes
52
capdecam
no/yes
53
capdecls
no/yes
54
gv2posok
no/yes
Table Name
PIC Table Type
ISM_MCFG
Menu Name
Status
1
ism_cflt
0 to 1
2
del_ismc
0 to 1
3
com_tout
0 to 255
4
star_typ
0 to 3
5
6
7
scycd_en
0 to 1
8
rla
10 to 5000
9
mot_lra
100 to 65535
10
lrs_del
1 to 10
11
str_lra
100 to 65535
12
rlv
200 to 13800
13
cu_th
5 to 100
14
vu_th
1 to 10
15
ct_ratio
3 to 1000
16
vt_rat
1 to 115
17
cu_per
1 to 10
18
vu_per
1 to 10
19
lfref_en
0 to 1
20
linefreq
0 to 1
21
gfp_en
0 to 1
22
gf_amps
1 to 25
23
gfp_pers
1 to 10
24
gfs_del
1 to 20
25
gfct_rat
150 to 150
26
ovvol_th
105 to 115
27
udvol_th
85 to 95
28
ovud_per
1 to 10
29
uvs_del
1 to 4
Instance
HMI Menu Path
12H
12
//MAINMENU/
Default
Unit
Note Menu text description
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Instance
HMI Menu Path
12H
13
//MAINMENU/MAINTAIN/
Default
Unit
Note Menu text description
0
-
0
-
60
sec
0
-
-
-
0
-
200
AMPS
1000
AMPS
5
cycles
2000
AMPS
460
Volts
15
%
5
%
100
-
1
-
5
sec
5
sec
0
-
0
-
1
-
15
AMPS
5
cycles
10
cycles
150
-
115
%
85
%
5
sec
1
sec
Oil Pump Req Prestart
Pump Req Startup
Pump Req Shutdown
Pump Req Swift Rst
Evap Pump Req Startup
Evap Pump Req Diagnostic
Evap Pump Req Frozen
Evap Pump Req Shutdown
Evap Pump Req Pumpdown
Cond Pump Req Prestart
Cond Pump Req Startup
Cond Pump Req Override
Cond Pump Req Shutdown
Cond Pump Req Tower
Cond Pump Req Diagnostic
Cond Pump Req Frozen
Cond Pump Req Pumpdown
Capacity Inhibit Ramping
Capacity Inhibit Demand
Capacity Decrease Demand
Guide Vane Inh Surge
Capacity Decrease Surge
Capacity Inh Low SST
Capacity Dec Low SST
Capacity Inh Cond Pres
Capacity Dec Cond Pres
Capacity Inh Motor Temp
Capacity Dec Motor Temp
Capacity Inh Hi Current
Capacity Dec Hi Current
Capacity Dec Low Temp
GV2 Pos at Startup OK
ISM Config Conflict
Delete ISM Config
Communication Timeout
Starter Type
Full Volt=0, Redu Volt=1
Solid State=2, FS VFD=3
Single Cycle Dropout
Motor Rated Load Amps
Motor Locked Rotor Trip
Locked Rotor Start Delay
Starter LRA Rating
Motor Rated Line Voltage
Current Imbal Threshold
Voltage Imbal Threshold
Motor Current CT Ratio:1
Volt Transformer Ratio:1
Current Imbal Persist
Voltage Imbal Persist
Line Frequency Faulting
Frequency(N=50Hz Y=60Hz)
Ground Fault Protection
Ground Fault Current
Ground Fault Persistence
Ground Fault Start Delay
Ground Fault CT Ratio:1
Overvoltage Threshold
Undervoltage Threshold
Over Under Volt Persist
Under Volt Start Delay
Low
High
CCN
LEN
Limit
Limit
Force
Force
Low
High
CCN
LEN
Limit
Limit
Force
Force
0
1
0
1
x
0
255
0
3
0
1
10
5000
100
65535
1
10
100
65535
200
13800
5
100
1
10
3
1000
1
115
1
10
1
10
0
1
0
1
0
1
1
25
1
10
1
20
150
150
105
115
85
95
1
10
1
4
65