Carrier PIC 5+ User Manual page 64

Control for 19 series centrifugal chiller
Table of Contents

Advertisement

Table Name
PIC Table Type
MAIISMH
Menu Name
Status
VOLT_H3
17
18
ld_amp1
19
ld_amp2
20
ld_amp3
21
bus_volt
Table Name
PIC Table Type
MAIN_SRD
Menu Name
Status
1
diff_tgt
2
diffault
3
diff_alm
srd_a
4
5
srd_1
6
srd_2
7
lift_a
8
lift_1
9
lift_2
10
strt_tmr
11
stalltmr
Table Name
PIC Table Type
TEMP_CAL
Menu Name
Status
1
ECW
2
ECW_RAW
3
ecw_off
-2.0 to 2.0
4
LCW
5
LCW_RAW
6
lcw_off
-2.0 to 2.0
7
ECDW
8
ECDW_RAW
9
ecdw_off
-2.0 to 2.0
10
LCDW
11
LCDW_RAW
12
lcdw_off
-2.0 to 2.0
Table Name
PIC Table Type
MAIOTHER
Menu Name
Status
1
tran_v
2
evapp_v
3
condp_v
econp_v
4
5
diffp_v
6
opsmp_v
7
opdis_v
8
evewp_v
9
evlwp_v
10
cdewp_v
11
cdlwp_v
12
brgip_v
brgop_v
13
14
pumpo_v
15
pumpi_v
16
last_cpt
17
pre_chck
no/yes
18
gvpos_ok
no/yes
19
pmppd_ok
no/yes
20
hgbp_ok
no/yes
21
dmp_ok
no/yes
op_heat
no/yes
22
64
Instance
HMI Menu Path
12H
8
//MAINMENU/MAINTAIN/
Default
Unit
Note Menu text description
Volts
AMPS
AMPS
AMPS
Volts
Instance
HMI Menu Path
12H
9
//MAINMENU/MAINTAIN/
Default
Unit
Note Menu text description
%
-
-
%
%
%
^F
^F
^F
min
min
Instance
HMI Menu Path
12H
10
//MAINMENU/MAINTAIN/
Default
Unit
Note Menu text description
°F
°F
^F
°F
°F
^F
°F
°F
^F
°F
°F
^F
Instance
HMI Menu Path
12H
12
//MAINMENU/
Default
Unit
Note Menu text description
Volts
Volts
Volts
Volts
Volts
Volts
Volts
Volts
Volts
Volts
Volts
Volts
Volts
Volts
Volts
-
-
-
-
-
-
-
Line Voltage Phase 3
Load Current Phase 1
Load Current Phase 2
Load Current Phase 3
DC Bus Voltage
Diffuser Target Pos
Diffuser Fault
SRD Rotating Stall Alarm
Calculated SRD Position
Calc High Lift SRD Pos
Calc Low Lift SRD Pos
Actual Lift
VDO High Lift Load Line
VDO Low Lift Load Line
VDO Logic Start Delay
SRD Stall Closure Time
Entering Chilled Water
ECW Sensor Raw Temp
ECW Temperature Offset
Leaving Chilled Water
LCW Sensor Raw Temp
LCW Temperature Offset
Entering Condenser Water
ECDW Sensor Raw Temp
ECDW Temperature Offset
Leaving Condenser Water
LCDW Sensor Raw Temp
LCDW Temperature Offset
5V Sensor Power Monitor
Evap Pres Trans Volts
Cond Pres Trans Volts
Econ Pres Trans Volts
Diffuser Pres Tran Volts
Oil Sump Pres Tran Volts
Oil Sup Pres Trans Volts
Evap Enter Water Volts
Evap Leave Water Volts
Cond Enter Water Volts
Cond Leave Water Volts
Bearing In Trans Volt
Bearing Out Trans Volt
Pump Output Trans Volt
Pump Input Trans Volt
Last Cond Pump Run Time
Prestart Check Status
GV1 Pos at Startup OK
Pump PD at Startup OK
ECV Pos at Startup OK
Damper Pos at Startup OK
Oil Pump Req Oil Heater
Low
High
CCN
LEN
Limit
Limit
Force
Force
Low
High
CCN
LEN
Limit
Limit
Force
Force
Low
High
CCN
LEN
Limit
Limit
Force
Force
-2
2
x
-2
2
x
-2
2
x
-2
2
x
Low
High
CCN
LEN
Limit
Limit
Force
Force