Table 4-4 LANVIEW LED Diagnostic Indications (continued)
LED
Color
UP
Off
Green
Manager
Off
Green
RPS
Off
Amber
State
No valid connection to switch stack down
connector.
Solid. Valid connection to switch stack down
connector.
Blinking. Information is being transferred
through the high-speed stacking cable.
Switch is operating as a Member in the stack.
Solid. Switch is operating as the Manager of
the stack.
Connected C2RPS-POE supply not in use.
Internal power supply failed.
Solid. The switch internal power supply failed,
and the RPS is providing the proper power to
the switch.
Recommended Action
1. Make sure the switch connected to
the stack down connector is
powered on.
2. Replace cable with a known good
one.
3. If the problem still exists, contact
Enterasys Networks for technical
support.
None.
None.
None.
None.
If a C2RPS-POE RPS is connected to
the switch, it should be providing
power. To determine if there is a
problem, perform the following:
1. Ensure the RPS is powered on.
2. Ensure that the AC power cord to
the RPS is plugged in correctly and
that there is power at the AC power
source.
3. Replace the power cord with a
known good one.
4. Ensure the DC power cable
(C2RPS-POE) from the RPS to the
switch is plugged in correctly.
5. If the problem persists, contact
Enterasys Networks for technical
support.
None.
SecureStack B2 Installation Guide 4-5
Using LANVIEW
Need help?
Do you have a question about the SecureStack B2 B2G124-48P and is the answer not in the manual?
Questions and answers