USER RESTART MONITORED (max number = 16)
The USER RESTART MONITORED operator is used to save
the restart signal (coming from a RESTART command
device) according to the following truth table.
Clear
Restart
1
X
X
X
0
0
0
Parameters
Clear enable: If selected, enables an input to reset the memorization.
Restart request: If selected, it enables an output that can be used to signal the possibility of
performing the Restart. The behaviour can be of type 1 or type 2 as represented in the truth table.
*This output uses a system timer
MACRO RESTART MANUAL (max number = 16)
The MACRO RESTART MANUAL operator is used to combine a logic
gate chosen by the user with the Restart Manual functional block
("USER RESTART MANUAL") in accordance with the following truth
table.
Clear
Restart Logic Out
1
X
0
Rising Edge
0
68
STAND ALONE PROGRAMMABLE SAFETY CONTROLLER
In
Q
X
0
0
0
1
Keep Memory
1
1
Input Logic Out
X
X
0
Restart Request Type 1
0
0
1
0
Output
X
0
0
0
1
Keep memory
1
1
Restart Request Type 2*
1
1
Blinking 1Hz
0
Restart Request
0
0
1
0
8541403 • 19/07/2021 • Rev.1