EBARA 25EVMS85.37 Instruction Manual page 7

Stainless steel vertical multi-stage pump
Table of Contents

Advertisement

■ Standard specifications
Liquid handled
Suction total head *3
(20℃)
Maximum working pressure
Standard allowable
suction pressure
Impeller
Casing
Construction
Shaft seal
Bearing
Flange
Lower casing
Intermediate casing
Impeller
Shaft sleeve
Material
Shaft
Wear ling
Phase / pole
Motor
Voltage
*4
Type
*5
Efficiency
Installation location
*1
Fresh water refers to tap water, industrial water or well water, with a temperature of 0 to 80C, a
pH of 5.8 to 8.6 and a chlorine ion concentration of 200 mg/L or less.
Contact EBARA regarding low-temperature liquid between -15 and 0C and high-temperature
liquid exceeding 80℃.
*2
Liquid that is not a slurry, not containing solid material (special specifications arise depending on
the property of the liquid)
The pump's total suction head is shown at a water temperature of 20℃. When the water differs
*3
from this temperature, and for particular hot water temperatures, suction performance is reduced.
Please discuss the situation with EBARA.
The tolerance value for voltage fluctuations is 5% or less, and the tolerance value for frequency
*4
fluctuations is 2% or less. For simultaneous fluctuations of voltage and frequency, the sum of
their absolute values is within 5%. However in either case, the motor's characteristics,
temperature rise, etc. are not in accordance with the rated values.
Fresh water (pH: 5.8 to 8.6) *1 cutting lubricant, cleaning fluid etc *2
-15C to 120C
Model EVMS/EVMSL pumps conform to the "Permeability standards for
water supply unit equipment" as per the Japanese Water Works Law.
Other than followings : -6 m
【50Hz】50EVMS...371~400L/min : -5 m
401~480L/min : -3 m
【60Hz】32EVMS...141~160L/min : -5 m
40EVMS...281~300L/min : -5 m
50EVMS...281~400L/min : -5 m
401~440L/min : -4 m
441~500L/min : -2 m
Refer to table 2.1~2.2.
Closed, single liner
Lower: Inline
Intermediate: Return vane
Mechanical seal
Upper: sealed ball bearing (motor interior)
lower: submarged sleeve bearings
25, 32, 40, 50 :
Equivalent to JIS10K
standard
Equivalent to JIS20K
Model EVMS : SUS304
Model EVMS : SUS304
(But 32EVMS(L)1967.5 and 9 stages or higher models of 50EVMS(L)
use SUS329A)
Model EVMS : PPS / SUS304
3 phase / 2 pole
50Hz : 200V
60Hz : 200/220/230V
Totally enclosed fan cooling type (outdoor)
IE3 (Premium efficiency)
Indoor or outdoor, ambient temperature 0 to 40C
Relative humidity 85% (no condensation)
Altitude 1,000 m or less
There should be no corrosive or explosive gas, steam, etc.
- 7 -
Models with maximum working pressure 1.37
2
MPa {14 kgf/cm
} or less
Models with maximum working pressure 2.45
2
MPa {25 kgf/cm
} or less
Model EVMSL : SUS316
Model EVMSL : SUS316
Model EVMSL : PPS / SUS316
*6 *7
EBARA
EVMS/EVMSL
CORPORATION

Advertisement

Table of Contents
loading

This manual is also suitable for:

25evms125.5525evms165.7525evms2551.125evms3351.525evms3952.225evms45.37 ... Show all