Be sure to issue the customer's
pump operation personnel with
copies of this manual
EBARA Stainless Steel Vertical
Multi-Stage Pump
Model EVMS/EVMSL
Instruction Manual
Thank you for choosing the EBARA Model EVMS/EVMSL Stainless Steel Vertical Multi-stage Pump. EBARA
takes every caution in manufacturing the product for safe use by the customer. However, handling this pump
in an inappropriate manner may reduce its functional capacity and result in an accident.
This operation manual explains the proper procedures concerning the installation, operation, and
maintenance of the product. This manual should be read before conducting operation and maintenance and
inspections on this pump.
Installation personnel must provide copies of this manual to the customer's pump operation, maintenance and
inspection personnel. Keep this manual in a safe place where it can be consulted at any time.
Be sure to issue the customer's pump operation, maintenance, and inspection personnel with copies of this
manual.
Contents
Warnings ............................
Safety Cautions ......................
Delivery checks ......................
1. Pump ................................ 5
2. Nameplate ........................... 5
Specifications ........................
Installation ..........................
1. Installation location ................... 11
2. Piping .............................. 11
3. Electrical wiring ...................... 13
Operation ...........................
1. Prior to start up ...................... 14
2. Operation ........................... 16
3. Stopping ............................ 16
4. Operate cautions .................... 16
CAUTION
To installation personnel:
Maintenance ........................
2
3
1. Daily inspection ...................... 17
5
3. Consumable parts .................... 19
Trouble shooting ....................
Construction .......................
6
11
10
1. Disassembly ......................... 23
2. Reassembly ......................... 24
Limited warranty ....................
11
14
- 1 -
CF1212U-H001 REV.1
EBARA
CORPORATION
17
20
21
26

Advertisement

Table of Contents
loading

Summary of Contents for EBARA 25EVMS85.37

  • Page 1: Table Of Contents

    Instruction Manual CAUTION Thank you for choosing the EBARA Model EVMS/EVMSL Stainless Steel Vertical Multi-stage Pump. EBARA takes every caution in manufacturing the product for safe use by the customer. However, handling this pump in an inappropriate manner may reduce its functional capacity and result in an accident.
  • Page 2: 1 Warnings

    EVMS/EVMSL 1 Warnings Warnings in this manual provide information needed for safe operation of the pump, and instructions for preventing danger or injury to you or other people. So that you will know the degree and imminence of danger that warnings signify, they are divided into two grades, WARNING and CAUTION, according to the seriousness of what will happen if their instructions are not heeded.
  • Page 3: 2 Safety Cautions

    In facilities with living matter (fish farms, fish preserves, aquariums, etc.), always prepare a spare pump, as oxygen deprivation may result due to pump failures. EBARA CORPORATION - 3 -...
  • Page 4 To prevent an accident if the pump stops running or an abnormality occurs, immediately turn off the power switch. Contact the shop from where you ordered the pump, or EBARA to perform an inspection and maintenance on the pump. When the pump is out of use for prolonged periods such as the wintertime, water inside the pump could freeze, causing damage to the pump.
  • Page 5: 3 Delivery Checks

    Do not operate 50 Hz pumps at 60 Hz. The pump will overload, and the motor will burnout. Caution Do not operate 60 Hz pumps at 50 Hz. Pump performance will suffer. Title (EBARA Pump) Serial number Model Rated output (kW) Speed(min...
  • Page 6: 4 Specifications

    EVMS/EVMSL 4 Specifications Refer to the nameplate for the head, capacity (CAP.) and speed, etc. of the pump you have purchased. Additional specifications are indicated in the following table. The pressure units used in this manual are as per the International System of Unit (SI). Reference values are also provided in the brackets.
  • Page 7 Fresh water refers to tap water, industrial water or well water, with a temperature of 0 to 80C, a pH of 5.8 to 8.6 and a chlorine ion concentration of 200 mg/L or less. Contact EBARA regarding low-temperature liquid between -15 and 0C and high-temperature liquid exceeding 80℃.
  • Page 8 Avoid a rotational speed range in which the pump and motor resonate during normal operation. 0.75 kW or higher models is cleared the Top Runner Standards. 0.55 kW or less models is equivalent to premium efficiency (EBARA own setting). ■ Optional specifications Different NBR (Liquid temperature : 0℃~60℃), EPDM...
  • Page 9 0.48 655.5 50EVMS(L)857.5 0.18 857.5 50EVMS(L)12511 0.67 50EVMS(L)17515 0.08 50EVMS(L)151.5 1.19 12.1 50EVMS(L)253.0 1.02 10.4 151.5 50EVMS(L)354.0 0.85 253.0 9511 50EVMS(L)455.5 0.68 354.0 13515 50EVMS(L)657.5 0.34 455.5 16518 50EVMS(L)9511 0.90 657.5 50EVMS(L)13515 0.22 50EVMS(L)16518 0.00 - 9 - EBARA CORPORATION...
  • Page 10 EVMS/EVMSL ■Table 2.1 Maximum working pressure and Standard allowable suction pressure (60Hz) Maximum working pressure Standard allowable suction pressure Size Model 1.37MPa(14kgf/cm 2.45MPa(25kgf/cm kgf/cm 25EVMS(L)56.37 0.96 25EVMS(L)76.55 0.80 56.37 25EVMS(L)106.75 0.56 76.55 2061.5 25EVMS(L)1461.1 106.75 2962.2 0.24 1461.1 25EVMS(L)2061.5 0.84 25EVMS(L)2962.2 0.11 25EVMS(L)26.37...
  • Page 11: 5 Installation

    (4) If there is a risk that foreign substance is mixed in fluid, attach a strainer on the suction side. In addition, so that the strainer is not clogged , clean it regularly. - 11 - EBARA CORPORATION...
  • Page 12 EVMS/EVMSL (5) If thermal insulation is added to the piping, do not apply it to the motor. Also, if it is installed near the boiler, prevent the heat from the boiler to the pump (6) When installing a pump near the source of heat, please make sure that the heat from a source of heat won't be transmitted to a pump.
  • Page 13: Electrical Wiring

    (2) Please install an overload safety device in accordance with electrical equipment technical standards and interior wiring regulations. (3) Check the following conditions before turning on the switch: (a) Installation of appropriate fuses. (b) Correct wiring. (c) Correct grounding. - 13 - EBARA CORPORATION...
  • Page 14: 6 Operation

    EVMS/EVMSL 6 Operation Do not operate the pump for more than 1 minute with the discharge valve left closed. The pressure within the pump will rise, and the casing or plugs may be damaged. Do not touch the rotating parts such as the spindle, shaft couplings, V-pulleys, etc.
  • Page 15 We have priming set by sold separately; without hose. Please order. (4) When priming, manually rotate the unit, completely removing air from inside the impeller. (5) The coupling guard must be installed for operation. Injuries could result. - 15 - EBARA CORPORATION...
  • Page 16: Operation

    EVMS/EVMSL 2. Operation (1) Close the discharge valve when priming is complete. Completely open the suction valve for flooding or positive suction. (2) Turn the switch OFF and ON several times, and check that there are no problems with rotation direction or operating conditions. Note The correct rotational direction is clockwise looking from the motor.
  • Page 17: 7 Maintenance

    Caution Contact the shop from where you ordered the pump, or EBARA to perform an inspection and maintenance on the pump. When the pump is out of use for prolonged periods such as the wintertime, water inside the pump could freeze, causing damage to the pump.
  • Page 18: Long-Term Pump Stoppage And Storage

    Probable causes are strains in the piping and loose anchor bolts. Ebara offers Ebara vibration absorber frames, Ebara flex joints, and Ebara pipe silencers (pressure pulsation absorbers); if vibration absorption measures are necessary, the user may want to order these items.
  • Page 19: Consumable Parts

    6207 ZZ C3 6305 ZZ C3 6308 ZZ C3 6306 ZZ C3 6308 ZZ C3 6306 ZZ C3 6310 ZZ C3 6208 ZZ C3 6310 ZZ C3 6208 ZZ C3 18.5 6310 ZZ C3 6208 ZZ C3 - 19 - EBARA CORPORATION...
  • Page 20: 8 Troubleshooting

    Review the plan. Discharge head is too high for the pump. High fluid temperature or volatile fluid. Review the plan. Cavitation. Consult with EBARA. Not primed sufficiently. Sufficiently prime the pump. Water is Air is being sucked in. Inspect, repair suction piping and shaft seal.
  • Page 21: 9 Construction

    9 Construction This figure shows a typical model EVML-E pump; there may be some differences from this figure depending on its model size. EBARA has prepared sectional views with the material names for components. Please request copies. - 21 -...
  • Page 22 EVMS/EVMSL Material No./ Part name 1Unit EVMS EVMSL Casing cover SUS304 SUS316 Suction casing SUS304 SUS316 Intermediate casing SUS304 SUS316 N-Bn-1 ※1 Intermediate casing bearing SUS304 SUS316 Discharge casing SUS304 SUS316 Bottom casing SUS304 SUS316 Outer casing SUS304 SUS316 ※2 Impeller SUS304 SUS316...
  • Page 23: Mechanical Seal Replacement Procedures

    Never disassemble motor. When disassembly Caution necessary, contact EBARA. 1. Disassembly For disassembly, refer to the construction in . and follow the procedure below. (1) Turn the power OFF. (2) Remove the cover on the motor terminal box, and remove the external wiring.
  • Page 24: Reassembly

    Assembly is performed in the reverse order of disassembly. Note the following points however. Strict airtight inspections are necessary in assembly of the cartridge mechanical seal. Therefore, ask EBARA to perform this work. Note Replace the O-ring with new one during re-assembly.
  • Page 25 (a total of 4 on both sides, 130-2). The cartridge mechanical seal (111) can be requested from the store from which you purchased this item. (Refer to . Maintenance for a table of dimensions) - 25 - EBARA CORPORATION...
  • Page 26: Limited Warranty

    (6) months after Ex-factory, it shall be valid for twelve (12) months after delivery date to customer. (2) Under warranty term, EBARA will supply new replacing pump or parts free of charge in conditions that the cause of trouble is obviously recognized due to our design/ manufacture error, and the user operates pumps properly.