(c)With sucking with priming set
As shown on diagram below, piping from priming plug.
Connect the hose to the hose nipple.
Fully open the air vent plug and ball valve.
Prime by pressurization from the hose.
Close ball valve after confirming that water comes out from the air vent plug.
Close the air vent plug.
air vent plug
Note
We have priming set by sold separately; without hose. Please order.
(4) When priming, manually rotate the unit, completely removing air from inside the impeller.
(5) The coupling guard must be installed for operation. Injuries could result.