Chapter 5 Troubleshooting; Installation Check-Out - Cabletron Systems HubSTACK SEHI-34 User Manual

10base-t intelligent stackable hub
Hide thumbs Also See for HubSTACK SEHI-34:
Table of Contents

Advertisement

This chapter contains instructions for using LANVIEW LEDs to
troubleshoot physical layer network problems. It also describes how to
reset the SEHI.

5.1 INSTALLATION CHECK-OUT

After you connect the SEHI to the network, verify that packets pass
between all Ethernet devices connected to the SEHI and any other
devices connected to the network. If you encounter difficulty with any
of the attached devices, check the link as follows:
1. Check that the LNK LED, if applicable, for the port is on. If the
LED is not on:
a. Check that the 10BASE-T device at the other end of the twisted
pair segment is powered up.
b. Verify that the connector on the twisted pair segment has the
proper pinouts. Refer to Chapter 2 for the pin assignments for
twisted pair connectors.
For EPIM-F1/EPIM-F2 check that the TX and RX fibers are
properly connected.
c.
Check the cable for continuity. A variety of tools are available
for this test, depending on the media you are using.
d. Check that the twisted pair segments meet cable specifications
for dB loss described in Chapter 2.