10 Technical Data
10.1.3
Ambient Conditions and Classifications
The following ambient conditions and classifications for the L-509 must be observed:
Area of application
Maximum altitude
Relative humidity
Storage temperature
Transport temperature
Supply fluctuations
Degree of pollution
Degree of protection
according to IEC 60529
10.1.4
Limit Switch Specifications
Type
Supply voltage
Signal output
Signal logic
10.1.5
Reference Point Switch Specifications
Type
Supply voltage
Signal output
Signal logic
L-509 Stage
For indoor use only
2000 m
Max. 80 % for temperatures up to 31 °C
Linearly decreasing to 50 % at 40 °C
0 °C to 80 °C
0 °C to 80 °C
Max. ±10 % of the nominal voltage
2
IP40
Optical sensor
+5 V / ground
TTL level
The signal level changes when passing the limit switch. The
signal logic is active high. That means:
Normal motor operation: low (0 V)
Limit switch reached: high (+5 V)
Optical sensor
+5 V / GND, supply via the motor connector
TTL level
Direction sensing by means of different signal levels on the
left and right side of the reference point switch: The signal
level changes from 0 to +5 V when the reference point
switch is passed.
MP141E
Version: 1.1.0
51