5 Installation
5.7

Connecting the Power Supply to the L-509

Connecting a power supply is only necessary for the L-509.xxADxx models.
Requirements
 The power cord is not connected to the power socket.
Tools and accessories
Supplied components:
If one of the components supplied for connection to the power source has to be
replaced: Use a sufficiently measured and certified replacement component. Details:

Connecting the power supply to the L-509

 Attach the snap-on ferrite suppressor to the cable that is attached to the power supply:
a) Lay the cable approx. 50 mm from the barrel connector into the opened snap-on
b) Align the cable so that it is not squeezed when the snap-on ferrite suppressor is
c) Carefully press the two halves of the snap-on ferrite suppressor around the cable
 Connect the M8 connector (f) of the adapter to the M8 panel plug of the L-509.
 Connect the barrel connector of the adapter to the barrel connector socket of the
power supply.
 Connect the power cord to the power supply.
32
Version: 1.1.0
24 V wide-range-input power supply
Adapter for the power supply connection; barrel connector, 5.5 mm x 2.1 mm to
M8 4-pin (f)
Snap-on ferrite suppressor
Power cord
Power supply: Output 24 V DC, maximum output current 5 A
Snap-on ferrite suppressor: Impedance at 25 MHz: Approx. 176 Ω
Power cord: Three wires, cable cross section at least 3 × 0.75 mm
maximum length 2 m