5 Installation
5.5.2

Setting Up an XY System

NOTICE
Screws that are too long!
Screws and locating pins that are inserted too deeply can damage the lower stage.
 Observe the depth of the mounting holes in the motion platform (p. 52) of the lower
stage.
 Only use screws and locating pins of the correct length for the respective mounting
holes.
Designations in these instructions:
Lower stage: Forms the basis of the multi-axis system (X axis), is attached to a surface
Upper stage: Forms the Y axis of the multi-axis system, is attached to the lower stage
rotated by 90°
Figure 8: Example of an XY system consisting of two L-509
Requirements
 You have read and understood the general notes on installation (p. 17).
 You have read and understood the general notes on setting up a multi-axis system (p.
25).
 You have accounted for the space required to route cables without bending and
according to regulations.
 You have properly mounted the lower stage onto a surface (p. 19).
Tools and accessories
4 screws, ISO 4762 M4x14 from the scope of delivery of the upper stage
Allen wrench AF 3