How to Operate the Function Menu

The function menu control zone includes 4 function menu buttons: Utility, Measure,
Acquire, Cursor, and 2 immediate-execution buttons: Autoset, Run/Stop.

How to Set the Sampling/Display

Push the Acquire button, the Sampling and Display menu is shown in the right as follows:
Function Menu
Acqu Mode
Type
Persist
XY Mode
Counter
Persist
When the Persist function is used, the persistence display effect of the picture tube
oscilloscope can be simulated. The reserved original data is displayed in fade color and the
new data is in bright color.
(1) Push the Acquire button.
(2) In the right menu, press Persist to select the persist time, including OFF, 1 Second, 2
4.Advanced User Guidebook
Set Holdoff time as default value (100 ns).
Enter previous page
Setting
Description
Sample
Normal sampling mode.
Peak Detect
Use to capture maximal and minimal samples.
Finding highest and lowest points over adjacent
intervals. It is used for the detection of the jamming
burr and the possibility of reducing the confusion.
Average
It is used to reduce the random and don't-care
noises, with the optional number of averages. Turn
the M knob to select 4, 16, 64, 128 in the left menu.
Dots
Only the sampling points are displayed.
Vect
The space between the adjacent sampling points in
the display is filled with the vector form.
OFF
1 Second
2 Seconds
Set the persistence time
5 Seconds
Infinity
ON
Turn on/off XY display function
OFF
ON
Turn on/off counter