Fujitsu PRIMERGY RX2450 M1 Upgrade And Maintenance Manual page 216

Table of Contents

Advertisement

Appendix A
Jumper
JWD1
Watch Dog
14.4
Minimum startup configuration
Field Replaceable Units
(FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
System board
2 CPU with CPU heat
sink
1 memory module
Front panel module
1 PSU
Table 4: Minimum startup configuration - components
Cable
Front panel cable
Power cable
Table 5: Minimum startup configuration - cables
216
Status
Description
Default
NMI
Disabled
Notes
no TPM or expansion cards installed
installed in DIMM slot A2
installed in PSU bay PSU 1
Notes
Upgrade and Maintenance Manual
RX2450 M1

Advertisement

Table of Contents
loading

Table of Contents