Download Print this page
WEG CFW700 Reference Manual

WEG CFW700 Reference Manual

Quick parameter reference, faults and alarms
Hide thumbs Also See for CFW700:

Advertisement

Available languages

Available languages

Quick Links

Frequency Inverter
Convertidor de Frecuencia
Inversor de Frequência
CFW700
Referencia Rápida de los Parámetros, Fallas y Alarmas
Referência Rápida dos Parâmetros, Falhas e Alarmes
Motors | Automation | Energy | Transmission & Distribution | Coatings

Advertisement

loading

Summary of Contents for WEG CFW700

  • Page 1 Motors | Automation | Energy | Transmission & Distribution | Coatings Frequency Inverter Convertidor de Frecuencia Inversor de Frequência CFW700 Quick Parameter Reference, Faults and Alarms Referencia Rápida de los Parámetros, Fallas y Alarmas Referência Rápida dos Parâmetros, Falhas e Alarmes...
  • Page 2 Quick Parameter Reference, Faults and Alarms Series: CFW700 English Document: 10000849536 / 04 Software Version: 2.0X Date: 01/2017...
  • Page 4 Bit 13 = Special Bit 14 and 15 = Reserved P0030 IGBTs Temperature -20.0 to 150.0 °C READ 15-3 P0034 Internal Air Temperature -20.0 to 150.0 °C READ 15-3 P0036 Heatsink Fan Speed 0 to 15000 rpm READ 16-5 CFW700 | 3...
  • Page 5 150 (125) 12-4 12-5 P0123 JOG- Reference 0 to 18000 rpm 150 (125) Vector 12-5 P0132 Maximum Overspeed Level 0 to 100 % 10 % 12-5 P0133 Minimum Speed 0 to 18000 rpm 90 (75) rpm BASIC 12-6 4 | CFW700...
  • Page 6 0.0 to 350.0 % 125.0 % Vector 11-22 P0175 Flux Proportional Gain 0.0 to 31.9 Vector 11-16 P0176 Flux Integral Gain 0.000 to 9.999 0.020 Vector 11-16 P0178 Rated Flux 0 to 120 % 100 % Vector 11-16 CFW700 | 5...
  • Page 7 10 = Save User 2 P0205 Main Display Parameter 0 to 1199 Selection P0206 Secondary Display 0 to 1199 Parameter Selection P0207 Bar Graph Parameter 0 to 1199 Selection P0208 Main Display Scale Factor 0.1 to 1000.0 % 100.0 % 6 | CFW700...
  • Page 8 2 = LR Key LOC 3 = LR Key REM 4 = DIx 5 = Serial LOC 6 = Serial REM 7 = CO/DN/DP LOC 8 = CO/DN/DP REM 9 = SoftPLC LOC 10 = SoftPLC REM CFW700 | 7...
  • Page 9 5 = Application Function 1 6 = Application Function 2 7 = Application Function 3 8 = Application Function 4 9 = Application Function 5 10 = Application Function 6 11 = Application Function 7 12 = Application Function 8 8 | CFW700...
  • Page 10 1.000 13-6 P0256 AO2 Signal Type 0 = 0 to 10 V / 20 mA 13-8 1 = 4 to 20 mA 2 = 10 V / 20 mA to 0 3 = 20 to 4 mA CFW700 | 9...
  • Page 11 13-10 P0267 DI5 Function Refer to the P0263 options 13-10 P0268 DI6 Function Refer to the P0263 options 13-10 P0269 DI7 Function Refer to the P0263 options 13-10 P0270 DI8 Function Refer to the P0263 options 13-10 10 | CFW700...
  • Page 12 18 (15) rpm 13-22 P0292 N = N* Band 0 to 18000 rpm 18 (15) rpm 13-22 P0293 Tx Torque 0 to 200 % 100 % 13-22 P0294 Hx Time 0 to 6553 h 4320 h 13-22 CFW700 | 11...
  • Page 13 0 = 1.25 kHz According 1 = 2.5 kHz to the 2 = 5.0 kHz inverter 3 = 10.0 kHz model 4 = 2.0 kHz P0298 Application 0 = Normal Duty (ND) 1 = Heavy Duty (HD) 12 | CFW700...
  • Page 14 0.128 Vector 12-15 P0327 FS I/f Current Ramp 0.000 to 1.000 s 0.070 Sless 12-10 P0328 Flying Start Filter 0.000 to 1.000 s 0.085 Sless 12-10 P0329 FS I/f Frequency Ramp 2.0 to 50.0 20.0 Sless 12-10 CFW700 | 13...
  • Page 15 P0360 Speed Hysteresis 0.0 to 100.0 % 10.0 % Vector 11-23 P0361 Time with Speed different 0.0 to 999.0 s 0.0 s Vector 11-24 from Reference P0372 Sless DC Braking Current 0.0 to 90.0 % 40.0 % Sless 12-18 14 | CFW700...
  • Page 16 Leakage Inductance 0.00 to 99.99 mH 0.00 mH cfg, MOTOR 11-20 Vector P0412 T Time Constant 0.000 to 9.999 s 0.000 s Vector MOTOR 11-21 P0413 T Time Constant 0.00 to 99.99 s 0.00 s Vector MOTOR 11-21 CFW700 | 15...
  • Page 17 600 (525) cfg, V/f 9-14 P0591 Hysteresis for the 0 to 30 % 10 % cfg, V/f 9-14 Maximum Torque Level P0613 Firmware Revision -32768 to 32767 16-8 P0614 Revision of the PLD -32768 to 32767 16-8 16 | CFW700...
  • Page 18 P0705 CAN Controller Status 0 = Disabled 17-1 1 = Auto-baud 2 = CAN Enabled 3 = Warning 4 = Error Passive 5 = Bus Off 6 = No Bus Power P0706 Received CAN Telegrams 0 to 65535 17-1 CFW700 | 17...
  • Page 19 17-2 P0743 Profibus Reading # 4 0 to 1199 17-2 P0744 Profibus Reading # 5 0 to 1199 17-2 P0745 Profibus Reading # 6 0 to 1199 17-2 P0746 Profibus Reading # 7 0 to 1199 17-2 18 | CFW700...
  • Page 20 2 = EP 3 = Multispeed 4 = 3-Wire Start/Stop 5 = FWD Run/ REV Run 6 = Special Function Set P1008 Lag Error -9999 to 9999 ro, Enc SPLC 18-2 P1009 Position Gain 0 to 9999 SPLC 18-3 CFW700 | 19...
  • Page 21 18-3 P1056 SoftPLC Parameter 47 -32768 to 32767 SPLC 18-3 P1057 SoftPLC Parameter 48 -32768 to 32767 SPLC 18-3 P1058 SoftPLC Parameter 49 -32768 to 32767 SPLC 18-3 P1059 SoftPLC Parameter 50 -32768 to 32767 SPLC 18-3 20 | CFW700...
  • Page 22 Adj = Parameter available only in adjustable V/f mode. V V W = Parameter available in V V W mode. Vector = Parameter available in vector mode. Sless = Parameter available only in sensorless mode. Enc = Parameter available only in vector mode with encoder. CFW700 | 21...
  • Page 23 The inverter output current is too high. IGBT Overload Note: Alarm It can be disabled by setting P0350 = 0 or 2. „ F0048: It is the IGBT overload fault. The inverter output current is too high. IGBT Overload Fault 22 | CFW700...
  • Page 24 Loose connection or short-circuit (resistance < 100 Ω) - An analog input and an analog output in the wiring connected to the motor thermistors. „ must be set for the PTC function. Not installed motor thermistors. „ Blocked motor shaft. CFW700 | 23...
  • Page 25 Verify the network master status, making sure it is Profibus DP command from the Profibus DP network in the execution mode (Run). „ Interface in Clear master to enter the clear mode. Refer to the Profibus DP communication manual Mode for more information 24 | CFW700...
  • Page 26 Inverter in Torque Current Limitation for too long. Speed Error too Effective Speed greater than the setting in High P0360 for longer than P0361. „ A0170: The STO function (Safe Torque Off) is The CFW700 went to the STO state. Safety Stop active. CFW700 | 25...
  • Page 27 Verify whether the Profibus DP module is correctly Profibus DP Profibus DP communication module fit into the slot 3. „ Module Access data. The fault indication will occur if P0313 = 5. „ Error Refer to the Profibus DP communication manual for more information 26 | CFW700...
  • Page 28 To reduce the switching frequency (P0297). (2) With the Profibus DP module connected into the slot 3 (XC43). (3) Manual available for download on the website: www.weg.net. NOTE! The user parameters (P1010 to P1059), faults (F0750 to F0799) and alarms (A0750 to A0799) related to PID Control applications, Electronic Potentiometer (E.P.), Multispeed, Three-Wire Control (Start/...
  • Page 29 Quick Parameter Reference, Faults and Alarms 28 | CFW700...
  • Page 30 Referencia Rápida de los Parámetros, Fallas y Alarmas Série: CFW700 Español Documento: 10000849536 / 04 Versión de Software: 2.0X Data: 01/2017...
  • Page 32 Bit 9 = Relé Seguridad Bit 10 = (0)24 V/ (1) Bus Bit 11 = Siempre 0 Bit 12 = IGBT Frenado Bit 13 = Especial Bit 14 y 15 = Reservado P0030 Temperatura IGBTs -20,0 a 150,0 °C READ 15-3 CFW700 | 31...
  • Page 33 Desaceleración P0102 Tiempo Aceleración 2ª 0,0 a 999,0 s 20,0 s 12-1 Rampa P0103 Tiempo Desaceleración 0,0 a 999,0 s 20,0 s 12-1 2ª Rampa P0104 Tipo del Rampa 0 = Lineal 12-2 1 = Curva S 32 | CFW700...
  • Page 34 Frenado Reostático P0156 Corriente Sobrecarga 0,1 a 1,5xI 1,05xI 15-4 nom-ND nom-ND 100 % P0157 Corriente Sobrecarga 0,1 a 1,5xI 0,9xI 15-4 nom-ND nom-ND 50 % P0158 Corriente Sobrecarga 5 % 0,1 a 1,5xI 0,65xI 15-4 nom-ND nom-ND CFW700 | 33...
  • Page 35 P0191 Búsqueda del Cero 0 = Inactivo 12-20 Encoder 1 = Activa P0192 Estado Búsqueda Cero 0 = Inactiva READ 12-20 Encoder 1 = Concluido P0200 Contraseña 0 = Inactiva 1 = Activa 2 = Modificar Contraseña 34 | CFW700...
  • Page 36 Display Principal 1 = wxy.z 2 = wx.yz 3 = w.xyz 4 = Conforme P0511 5 = Conforme P0513 6 = Conforme P0515 7 = Conforme P0517 P0211 Factor Escala Display 0,1 a 1000,0 % 100,0 % Secundario CFW700 | 35...
  • Page 37 8 = CO/DN/DP (AH) 9 = SoftPLC (H) 10 = SoftPLC (AH) 11 = Polaridad AI2 P0224 Selección Gira/Para LOC 0 = Teclas I, O 13-25 1 = DIx 2 = Serial 3 = CO/DN/DP 4 = SoftPLC 36 | CFW700...
  • Page 38 3 = 20 a 4 mA 4 = -10 a 10 V P0239 Offset de la Entrada AI2 -100,00 a 100,00 % 0,00 % 13-3 P0240 Filtro de la Entrada AI2 0,00 a 16,00 s 0,00 s 13-3 CFW700 | 37...
  • Page 39 P0256 Señal de la Salida AO2 0 = 0 a 10 V / 20 mA 13-8 1 = 4 a 20 mA 2 = 10 V / 20 mA a 0 3 = 20 a 4 mA 38 | CFW700...
  • Page 40 Ver opciones en P0263 13-10 P0268 Función de la Entrada DI6 Ver opciones en P0263 13-10 P0269 Función de la Entrada DI7 Ver opciones en P0263 13-10 P0270 Función de la Entrada DI8 Ver opciones en P0263 13-10 CFW700 | 39...
  • Page 41 Ver opciones en P0275 13-16 P0281 Frecuencia Fx 0,0 a 300,0 Hz 4,0 Hz 13-20 P0282 Histerese Fx 0,0 a 15,0 Hz 2,0 Hz 13-21 P0287 Histerese Nx / Ny 0 a 900 rpm 18 (15) rpm 13-21 40 | CFW700...
  • Page 42 41 = 53 A / 44 A 42 = 63 A / 53 A 43 = 80 A / 66 A 44 = 107 A / 90 A 45 = 125 A / 107 A 46 = 150 A / 122 A CFW700 | 41...
  • Page 43 5 = Causa Falla P0314 Watchdog Serial 0,0 a 999,0 s 0,0 s 17-1 P0316 Estado Interf. Serial 0 = Inactivo 17-1 1 = Activo 2 = Error Watchdog P0317 Start-up Orientado 0 = No STARTUP 7-2 1 = Sí 42 | CFW700...
  • Page 44 6 = VD-ON, VI-CT 7 = VD-OFF, VI-ON 8 = VD-OFF, VI-CT 9 = VD-CT, VI-CT * 10 = VD-CT, VI-OFF * 11 = VD-CT, VI-ON * 12 = VD-ON, VI-CT * 13 = VD-OFF, VI-CT * CFW700 | 43...
  • Page 45 Corriente Nominal del 0 a 1,3xI 1,0xI MOTOR 11-9 nom-ND nom-ND Motor P0402 Rotación Nominal del 0 a 18000 rpm 1750 (1458) MOTOR 11-10 Motor P0403 Frecuencia Nominal del 0 a 300 Hz 60 (50) Hz MOTOR 11-10 Motor 44 | CFW700...
  • Page 46 Inductancia de Dispersión 0,00 a 99,99 mH 0,00 mH cfg, MOTOR 11-20 Vectorial P0412 Constante T 0,000 a 9,999 s 0,000 s Vectorial MOTOR 11-21 P0413 Constante T 0,00 a 99,99 s 0,00 s Vectorial MOTOR 11-21 CFW700 | 45...
  • Page 47 V/f 9-14 P0591 Histéresis para el Nivel 0 a 30 % 10 % cfg, V/f 9-14 Máximo de torque P0613 Revisión del Firmware -32768 a 32767 16-8 P0614 Revisión de la PLD -32768 a 32767 16-8 46 | CFW700...
  • Page 48 2 = 500 Kbps 3 = 250 Kbps 4 = 125 Kbps 5 = 100 Kbps/Auto 6 = 50 Kbps/Auto 7 = 20 Kbps/Auto 8 = 10 Kbps/Auto P0703 Reset de Bus Off 0 = Manual 17-1 1 = Automático CFW700 | 47...
  • Page 49 3 = Operacional 4 = Preoperacional P0740 Estado Comunicación 0 = Inactivo 17-2 Profibus 1 = Error de Acceso 2 = Offline 3 = Error de Configuración 4 = Error de Parámetro 5 = Modo Clear 6 = Online 48 | CFW700...
  • Page 50 11 = 45,45 kbit/s P0964 Identificación del Drive 0 a 65535 17-3 P0965 Identificación Perfil 0 a 65535 17-3 P0967 Palabra de Control 0000h a FFFFh 0000h 17-3 Profidrive P0968 Palabra Estado 0000h a FFFFh 0000h 17-3 Profidrive CFW700 | 49...
  • Page 51 18-3 P1033 Parámetro SoftPLC 24 -32768 a 32767 SPLC 18-3 P1034 Parámetro SoftPLC 25 -32768 a 32767 SPLC 18-3 P1035 Parámetro SoftPLC 26 -32768 a 32767 SPLC 18-3 P1036 Parámetro SoftPLC 27 -32768 a 32767 SPLC 18-3 50 | CFW700...
  • Page 52 V V W = Parámetro disponible en modo V V W. Vectorial = Parámetro disponible en el modo vectorial. Sless = Parámetro disponible solo en modo sensorless. Enc = Parámetro disponible solo en modo vectorial con encoder. CFW700 | 51...
  • Page 53 Carga Alta en los Observación: frecuencia. IGBTs Puede ser deshabilitada ajustando P0350 = 0 o 2. „ F0048: Falla de sobrecarga en los IGBTs. Corriente muy alta en la salida del convertidor Sobrecarga en los de frecuencia. IGBTs 52 | CFW700...
  • Page 54 Cortocircuito para el tierra en una o más fases Observación: Falta a la Tierra de salida; „ Puede ser deshabilitado ajustando Capacitancia de los cables del motor elevada, lo P0343 = 0. que ocasiona picos de corrientes en la salida. CFW700 | 53...
  • Page 55 Bit del registrador de comendo del PLC en cero (0). „ A0137: Alarma de timeout en las conexiones I/O Una o más conexiones del tipo I/O alocadas fueran Timeout Conexión del DeviceNet. para el estado de timeout. DeviceNet 54 | CFW700...
  • Page 56 Mal contacto en la conexión de la señal en los del rango de 4-20 mA. bornes. „ A0168: Diferencia entre la Referencia de Convertidor en Limitación de Corriente de Torque. Error de Velocidad Velocidad y la Velocidad Real mayor que la muy Alta programada en P0360. CFW700 | 55...
  • Page 57 Alta la programada en P0360 por un tiempo superior a P0361. „ A0170: Función la función STO (Safe Torque Off). El CFW700 fue para el estado STO. Parada de Seguridad „ A0177: Alarma para substituición del ventilador Número de horas máximo de operación del Substituición del...
  • Page 58 Disminuir la frecuencia de conmutación (P0297). (2) Con módulo Profibus DP conectado en el slot 3 (XC43). (3) Manual disponible para download en el sitio: www.weg.net. ¡NOTA! Los parámetros del usuario (P1010 a P1059), las fallas (F0750 a F0799) y las alarmas (A0750 a A0799) relacionados a las aplicaciones Controlador PID, Potenciómetro Electrónico (P.E.), Multispeed,...
  • Page 59 Referencia Rápida de los Parámetros, Fallas y Alarmas 58 | CFW700...
  • Page 60 Referência Rápida dos Parâmetros, Falhas e Alarmes Série: CFW700 Português Documento: 10000849536 / 04 Versão de Software: 2.0X Data: 01/2017...
  • Page 62 P0036 Velocidade Ventilador 0 a 15000 rpm READ 16-5 P0037 Sobrecarga do Motor 0 a 100 % READ 16-5 P0038 Velocidade do Encoder 0 a 65535 rpm READ 16-5 P0039 Contador Pulsos Enc. 0 a 40000 READ 16-6 CFW700 | 61...
  • Page 63 150 (125) Vetorial 12-5 P0132 Nível Máx. 0 a 100 % 10 % 12-5 Sobrevelocidade P0133 Velocidade Mínima 0 a 18000 rpm 90 (75) rpm BASIC 12-6 P0134 Velocidade Máxima 0 a 18000 rpm 1800 (1500) BASIC 12-6 62 | CFW700...
  • Page 64 0 = Com perdas cfg, 11-24 1 = Sem perdas Vetorial 2 = Hab./Desab. DIx P0185 Nível Regulação Ud 339 a 1000 V 800 V Vetorial 11-25 P0186 Ganho Proporcional Ud 0,0 a 63,9 26,0 Vetorial 11-25 CFW700 | 63...
  • Page 65 13 = Hz 14 = HP 15 = h 16 = W 17 = kW 18 = kWh 19 = H 20 = Conforme P0510 21 = Conforme P0512 22 = Conforme P0514 23 = Conforme P0516 64 | CFW700...
  • Page 66 2 = Tecla SG (H) 3 = Tecla SG (AH) 4 = DIx 5 = Serial (H) 6 = Serial (AH) 7 = CO/DN/DP (H) 8 = CO/DN/DP (AH) 9 = SoftPLC (H) 10 = SoftPLC (AH) 11 = Polaridade AI2 CFW700 | 65...
  • Page 67 P0239 Offset da Entrada AI2 -100,00 a 100,00 % 0,00 % 13-3 P0240 Filtro da Entrada AI2 0,00 a 16,00 s 0,00 s 13-3 P0246 Configuração da Entrada 0 = Inativa 13-23 em Frequência 1 = DI3 2 = DI4 66 | CFW700...
  • Page 68 13-6 P0256 Sinal da Saída AO2 0 = 0 a 10 V / 20 mA 13-8 1 = 4 a 20 mA 2 = 10 V / 20 mA a 0 3 = 20 a 4 mA CFW700 | 67...
  • Page 69 P0267 Função da Entrada DI5 Ver opções em P0263 13-10 P0268 Função da Entrada DI6 Ver opções em P0263 13-10 P0269 Função da Entrada DI7 Ver opções em P0263 13-10 P0270 Função da Entrada DI8 Ver opções em P0263 13-10 68 | CFW700...
  • Page 70 18 (15) rpm 13-22 P0292 Faixa para N = N* 0 a 18000 rpm 18 (15) rpm 13-22 P0293 Torque Tx 0 a 200 % 100 % 13-22 P0294 Horas Hx 0 a 6553 h 4320 h 13-22 CFW700 | 69...
  • Page 71 P0297 Freq. de Chaveamento 0 = 1,25 kHz Conforme 1 = 2,5 kHz modelo do 2 = 5,0 kHz inversor 3 = 10,0 kHz 4 = 2,0 kHz P0298 Aplicação 0 = Uso Normal(ND) 1 = Uso Pesado(HD) 70 | CFW700...
  • Page 72 12-15 P0327 Rampa Corr. I/f F.S. 0,000 a 1,000 s 0,070 s Sless 12-10 P0328 Filtro Flying Start 0,000 a 1,000 s 0,085 s Sless 12-10 P0329 Rampa Freq. I/f F.S. 2,0 a 50,0 20,0 Sless 12-10 CFW700 | 71...
  • Page 73 P0360 Histerese de Velocidade 0,0 a 100,0 % 10,0 % Vetorial 11-23 P0361 Tempo com Velocidade 0,0 a 999,0 s 0,0 s Vetorial 11-24 Diferente da Referência P0372 Corr. Fren. CC (Sless) 0,0 a 90,0 % 40,0 % Sless 12-18 72 | CFW700...
  • Page 74 P0411 Indutância Dispersão 0,00 a 99,99 mH 0,00 mH cfg, MOTOR 11-20 Vetorial P0412 Constante T 0,000 a 9,999 s 0,000 s Vetorial MOTOR 11-21 P0413 Constante T 0,00 a 99,99 s 0,00 s Vetorial MOTOR 11-21 CFW700 | 73...
  • Page 75 0 a 18000 rpm 600 (525) cfg, V/f 9-14 Energia P0591 Histerese Economia 0 a 30 % 10 % cfg, V/f 9-14 Energia P0613 Revisão do Firmware -32768 a 32767 16-8 P0614 Revisão da PLD -32768 a 32767 16-8 74 | CFW700...
  • Page 76 P0705 Estado Controlador CAN 0 = Inativo 17-1 1 = Auto-baud 2 = CAN Ativo 3 = Warning 4 = Error Passive 5 = Bus Off 6 = Não Alimentado P0706 Telegramas CAN RX 0 a 65535 17-1 CFW700 | 75...
  • Page 77 Leitura #8 Profibus 0 a 1199 17-2 P0748 Leitura #9 Profibus 0 a 1199 17-2 P0749 Leitura #10 Profibus 0 a 1199 17-2 P0750 Escrita #3 Profibus 0 a 1199 17-3 P0751 Escrita #4 Profibus 0 a 1199 17-3 76 | CFW700...
  • Page 78 18-2 P1009 Ganho de Posição 0 a 9999 SPLC 18-3 P1010 Parâmetro SoftPLC 1 -32768 a 32767 SPLC 18-3 P1011 Parâmetro SoftPLC 2 -32768 a 32767 SPLC 18-3 P1012 Parâmetro SoftPLC 3 -32768 a 32767 SPLC 18-3 CFW700 | 77...
  • Page 79 18-3 P1056 Parâmetro SoftPLC 47 -32768 a 32767 SPLC 18-3 P1057 Parâmetro SoftPLC 48 -32768 a 32767 SPLC 18-3 P1058 Parâmetro SoftPLC 49 -32768 a 32767 SPLC 18-3 P1059 Parâmetro SoftPLC 50 -32768 a 32767 SPLC 18-3 78 | CFW700...
  • Page 80 Adj = Parâmetro disponível apenas com V/f ajustável. V V W = Parâmetro disponível em modo V V W. Vetorial = Parâmetro disponível em modo vetorial. Sless = Parâmetro disponível apenas em modo sensorless. Enc = Parâmetro disponível apenas em modo vetorial com encoder. CFW700 | 79...
  • Page 81 Corrente alta na saída do inversor. Carga Alta nos Obs.: IGBTs Pode ser desabilitado ajustando P0350 = 0 ou 2. „ F0048: Falha de sobrecarga nos IGBTs. Corrente muito alta na saída do inversor. Sobrecarga nos IGBTs 80 | CFW700...
  • Page 82 P0351 = 0 ou 3. Mau contato ou curto-circuito (resistência < 100 Ω) - Necessário programar entrada e saída. na fiação ligada ao termistor do motor. „ analógica para função PTC. Termistor do motor não instalado. „ Eixo do motor travado. CFW700 | 81...
  • Page 83 „ M a i s i n f o r m a ç õ e s c o n s u l t a r m a n u a l d a comunicação Profibus DP 82 | CFW700...
  • Page 84 Alto que a programada em P0360 por um tempo superior a P0361. „ A0170: Função função STO (Safe Torque Off, O CFW700 foi para o estado STO. Parada de função parada de segurança). Segurança „ A0177: Alarme para substituição do ventilador Número de horas má...
  • Page 85 M a i s i n f o r m a ç õ e s c o n s u l t a r m a n u a l d a comunicação Profibus DP „ A0702: Consultar o manual da SoftPLC Inversor Desabilitado A0704: Dois Movimentos Habilitados A0706: Referência não Programada para SoftPLC 84 | CFW700...
  • Page 86 Reduzir a frequência de chaveamento (P0297). (2) Com módulo Profibus DP conectado no slot 3 (XC43). (3) Manual disponível para download no site: www.weg.net. NOTA! Os parâmetros do usuário (P1010 a P1059), as falhas (F0750 a F0799) e alarmes (A0750 a A0799) relacionados as aplicações Controlador PID, Potenciômetro Eletrônico (P.E.), Multispeed, Comando...