Psu Replacement - Western Digital Ultrastar Serv60+8 User Manual

Hide thumbs Also See for Ultrastar Serv60+8:
Table of Contents

Advertisement

User Guide
d) Slowly lower the IOM into the empty slot while being careful to keep it level. Do not to force it.
Figure 39: Installing the IOM
e) When the IOM is lowered fully, apply light pressure with both hands evenly on the IOM body, not the
handles, to seat the IOM in the connector. If the IOM won't seat correctly, DO NOT FORCE IT. Instead,
back the IOM out, check the pins to make sure none are damaged, and try again.
f) Once the IOM is seated properly in the slot, close the handles until they latch closed.
6. Push the chassis back into the rack. Verify that the fan have slowed to their regular RPM. This ensures
that the enclosure is back to its proper cooling settings.

4.3 PSU Replacement

Table 33: Replacement Procedure Info
Required Tools
None
1. Place the CMA into service position.
# of People Required
1
57
Time Required
60s
4
Part Replacement
4.3
PSU Replacement
Replacement Window
5 Minutes