4.13 Rails Replacement

Table 43: Procedure Info
Required Tools
Long T15 Torx Screwdriver
• # 2 Philips Screwdriver
• Long T10 Torx Screwdriver
• Cable Ties (for
configurations with greater
than 10 total cables)
• Tape Measure
• Level
1.
Place the CMA into service position.
a) Unlatch the CMA at the elbow connector by pressing the blue release button to unlatch the connector
from the rail.
Figure 249: Unlatching a CMA Connector
b) Swing the CMA away from the enclosure.
Required Parts
Reuse: M5 x 10mm T15
Torx screws
• Reuse:Included Washers
• Low-Profile M4 x 3.2mm
Philips screws (included
with rail assembly)
• Optional (if using CMA
Tray): M3 x 8mm T10 Torx
screws