Table 6: MVB Dimensions and Technical Data
MVB Model
Natural & Propane
Dimensions
B
D
E
F
G*
H*
K
M
N
P
R
V
Weight
Relief Valve Connection
Electrical Rating 240V 50Hz
Min Buffer Tank Capacity
Max Storage Tank Capacity
Litres Recovery Per Hour @
*Water and gas connections are NPT. An NPT to BSP adapter kit is supplied with the water heater.
910500
Input
MJ/h
527
Output
kW
126
mm
1092
mm
813
mm
889
mm
603
R1
R2
mm
mm
mm
mm
889
mm
152
mm
51
kg
272
RC¾
Amps
6.25
L
217
L
6511
30
°C rise
3617
40
°C rise
2713
50
°C rise
2170
60
°C rise
1809
65
°C rise
1669
70
°C rise
1550
75
°C rise
1447
80
°C rise
1356
85
°C rise
1277
24
910750
911000
911250
791
1054
1319
189
252
316
1245
1397
1549
965
1118
1270
1041
1194
1346
756
908
1060
R1
R1¼
R1¼
R2
R2½
R2½
150
368
150
1041
1232
1346
152
152
152
51
51
51
299
326
354
RC¾
RC¾
RC¾
6.25
6.25
6.25
326
434
544
9767
13022
16329
5426
7234
9072
4069
5426
6804
3256
4341
5443
2713
3617
4536
2504
3339
4187
2325
3100
3888
2170
2894
3629
2035
2713
3402
1915
2553
3202
911500
911750
912000
1582
1846
1990
379
442
476
1702
1905
2057
1422
1575
1727
1499
1651
1803
1213
1365
1518
R1¼
R2
R2
R2½
R2½
R2½
200
451
200
1499
1727
1880
152
229
229
51
127
127
381
426
454
RC¾
RC¾
RC¾
6.25
8.5
8.5
653
761
820
19585
22840
24597
10880
12689
13665
8160
9517
10249
6528
7613
8199
5440
6344
6833
5022
5856
6307
4663
5438
5856
4352
5076
5466
4080
4758
5124
3840
4478
4823