SQ 05.2
SQ 14.2 / SQR 05.2
AC 01.2 Intrusive Modbus RTU
5.3.2.
Parking frame
Application
5.3.3.
DS intermediate frame for double sealing
Application
SQR 14.2 Control unit - electromechanical
Figure 25: Parking frame, example with plug/socket connector and cover
Parking frame for safe storage of a disconnected plug or cover.
For protection against touching the bare contacts and against environmental
influences.
Figure 26: Electrical connection with DS intermediate frame
[1]
Electrical connection
[2]
DS intermediate frame
When removing the electrical connection or due to leaky cable glands, there is a
potential risk of ingress of dust and water into the housing. This is prevented
effectively by inserting the double sealed intermediate frame [2] between the
plug/socket connector [1] and the housing of the device. The enclosure protection
of the device (IP68) will not be affected, even if the electrical connection [1] is
removed.
Electrical connection
31