42
Process Image

Table 34: Control byte C1, All Versions, Except 750-637/000-004

Bit 7
0
MapPZD
MapPZD
DisCam1
DisCam2
SetCam1
SetCam2
EnableRef
0
Manual
Version 1.6.1
Bit 6
Bit 5
Enable Ref
Set
Cam2
Coding of Process Data
Coding of Process Data
Inhibit Cam Output 1
0:
Cam output 1 enabled.
1:
Cam output 1 inhibited.
Inhibit Cam Output 2
0:
Cam output 2 enabled.
1:
Cam output 2 inhibited.
Apply Cam Output 1
Set value applied as lower comparison value N1_LO for
Positive edge:
cam output 1 (N1).
Set value applied as the upper comparison value N1_HI
Negative edge
for cam output 1 (N1).
Apply Cam Output 2
Set value applied as lower comparison value N2_LO for
Positive edge:
cam output 2 (N2).
Set value applied as the upper comparison value N2_HI
Negative edge
for cam output 2 (N2).
Enable REF Input
The control system sets the EnableRef bit
The control system must enable EN_LATC (C0.0) or
EN_LAT_EXT (C0.1) with a positive edge
A positive edge is generated at input REF
After this, the next positive edge at input C or LATCH will
result in a capture or preload event
Reserved
Public
750-637 Incremental Encoder Interfaces
Control Byte C1
Bit 4
Bit 3
Set
Dis
Cam1
Cam2
Cam1
WAGO I/O System 750
Bit 2
Bit 1
Bit 0
Dis
MapPZD
MapPZD