Thermal Specifications
The table below shows the standard operating temperature ranges for the entire Digi Connect ME
family of embedded modules.
The lower standard operating temperature ranges are specified without restrictions, except
condensation must not occur.
The upper operating temperature limit depends on the host PCB layout and surrounding
environmental conditions. To simplify the customer's design process, a maximum case temperature
has been specified.
The maximum case temperature must remain below the maximum, measured at the location shown
in the figure below.
Standard Operating Temperature Ranges
Product
Digi Connect Wi-ME 9210
and Digi Connect ME 9210
Product
Digi Connect Wi-ME
and Digi Connect ME 9210
Measure Temperature Here
Operating Temperature Range
-40C to 75C no external thermal pad
-40C to 85C with external thermal pad
Maximum Case Temperature
Maximum Case Temperature
84C no external thermal pad
95C with external thermal pad