13. Remove (2) jumpers from their terminals (see
Figure 19). Jumpers will not be reused.
14. Disconnect the U5, V5, and W5 wires from
their terminals (see Figure 19).
TABLE ELEVATION
MOTOR (220V)
U3
U2
V2
W2
W3
V3
Figure 19. Table elevation motor wired for 220V.
(Motor Rewired for 440V)
15. Connect wires U5, V5, and W5 as shown in
Figure 20.
TABLE ELEVATION
MOTOR (440V)
U5
U2
V2
V5
To Electrical Box
W2
W5
Figure 20. Table elevation motor wired for 440V.
16. Close table elevation motor junction box.
Model G0866 (Mfd. Since 11/18)
U1
U5
V1
V5
W5
W1
To Electrical Box
Jumper
U3
U1
V1
(Motor Rewired for 440V)
W1
W3
V3
V2
V1
U2
W1
W2
V2
W2
U2
FEED MOTOR (220V)
17. Open feed motor junction box (see Figure 21).
TABLE ELEVATION
MOTOR (440V)
U3
U5
U2
V2
Figure 21. Feed motor junction box.
V5
W2
18. Remove (3) jumpers from their terminals (see
W5
Figure 22). One jumper will not be reused.
W3
V3
Jumper
FEED MOTOR (220V)
Figure 22. Feed motor wired for 220V.
19. Rearrange jumpers as shown in Figure 23.
U1
FEED MOTOR (440V)
Figure 23. Feed motor wired for 440V.
20. Close feed motor junction box.
21. Close electrical box and lower left access door.
U1
V1
W1
(Motor Rewired for 440V)
V2
U2
V1
U1
W1
W2
V2
W2
U2
V2
U2
V1
W1
U1
W2
V2
W2
U2
F
-17-