7.8.4. Setting an Action by Specifying a Direct Path
Command and Response
SET·/EVENTS/E<loc>.Action=<expression>
ç
pw·/EVENTS/E<loc>.Action=<expression>
æ
Parameters
The structure of the <expression>is:<node_path>.<property_or_method>=<value>.Propertiesandmethods
arehandledinthesameway:dot(.)standsafterthepathinbothcases,colon(:)isnotused.Donotuse
brackets for methods. The
<value>
parameter is optional in case of certain methods.
Example
ç SET/EVENTS/E1.Action=/MEDIA/VIDEO/XP.switch=I4:O1
æ pw/EVENTS/E1.Action=/MEDIA/VIDEO/XP.switch=I4:O1
7.8.5. Setting an Action by Linking Another Action
Command and Response
SET·/EVENTS/E<loc>.Action=<event_nr>
ç
pw·/EVENTS/E<loc>.Action=<event_nr>
æ
Parameters
The <event_nr>meansthenumber(location)ofthelinkedeventwithoutletter'E'.
Example
ç SET/EVENTS/E2.Action=1
æ pw/EVENTS/E2.Action=1
TheActionoftheE2EventissettobethesameassetatE1Event.
7.8.6. Setting an Action by Linking a Macro

DIFFERENCE:
ThiscommandisavailableforSW4-TPS-TX240-PlusonlyfromFWpackagev1.3.0b6.
Command and Response
SET·/EVENTS/E<loc>.Action=<macro_name>
ç
pw·/EVENTS/E<loc>.Action=<macro_name>
æ
Parameters
The
<macro_name>meansthenameofthemacrothatcanbeseeninLDC(seetheMacros
be queried by the GET
/CTRL/MACROS.<id>
Example
ç SET/EVENTS/E1.Action=Macro1
æ pw/EVENTS/E2.Action=Macro1
section) or can
command.
Appliedfirmwarepackage:v1.3.2b3 | LDCsoftware:v2.5.7b2
HDMI-TPS-TX200series–User'sManual
7.9. Event Manager Tool Kit
7.9.1. Setting the Delay
In most cases, the Action is performed immediately after the Condition is detected. But sometimes a delay
isnecessarybetweentheConditionandtheAction,thus,thefollowingdelayoptionsaredefined:
no delay
simple delay
still true after
continously
Command and Response (summary)
SET·/EVENTS/E<loc>.ConditionTimeout=<time>
ç
pw·/EVENTS/E<loc>.ConditionTimeout=<time>
æ
SET·/EVENTS/E<loc>.ConditionEndCheck=<true/false>
ç
pw·/EVENTS/E<loc>.ConditionEndCheck=<true/false>
æ
SET·/EVENTS/E<loc>.ConditionTimeoutContinuous=<true/false>
ç
pw·/EVENTS/E<loc>.ConditionTimeoutContinuous=<true/false>
æ
Parameters
The <time>parametermeansseconds.Setthefollowingpropertiesforthedesireddelaytype:
Delay type
no delay
/EVENTS/E<loc>.ConditionTimeout
simple delay
/EVENTS/E<loc>.ConditionTimeout
/EVENTS/E<loc>.ConditionTimeout
still true after
/EVENTS/E<loc>.ConditionEndCheck
/EVENTS/E<loc>.ConditionTimeout
continuously
true
/EVENTS/E<loc>.ConditionEndCheck
/EVENTS/E<loc>.ConditionTimeoutContinuous
Condition = true
Perform the action
Condition = true
Delay
Perform the action
Condition = true
Delay
Condition = true Perform the action
Condition = true
Perform the action
true
Delay
Propertiestoset
Value
0
The Action will be lanuched
after the Condition is detected.
<time>
If the Condition is detected, the
action will be launched after the
set time.
<time>
The Condition is fulfilled only
if is detected after the set time
true
again.
<time>
TheConditionisfulfilledonlyif
itisexistingcontinuouslyduring
true
the set time.
true
99
Time
Result