6.7. Serial Port Configuration
6.7.1. Setting the Control Protocol
SeemoreinformationabouttheRS-232modesintheSerialInterface
Command and Response
 {RS232=<mode>}
 (RS232=<mode>)CrLf
Parameters
Parameter
Parameterdescription
<mode>
Theserialportworkingmode
Thecurrentsettingcanbequeriedbythe{RS232=?} command.
Example
 {RS232=CONTROL}
 (RS232=CONTROL)
6.7.2. Serial Port Format Setting (Local port)
ThiscommandsetstheformatofthelocalRS-232port(Phoenix).
Command and Response
 {RS232_LOCAL_FORMAT=<baud_rate>;<data_bit>;<parity>;<stop_bit>}
 (RS232_LOCAL_FORMAT=<baud_rate>;<data_bit>;<parity>;<stop_bit>)CrLf
Parameters
Parameter
Parameterdescription
<baud_rate>
Baudratesetting(optional)
<data_bit>
Databitsetting(optional)
<parity>
Paritysetting(optional)
<stop_bit>
Stopbitsetting(optional)
The current setting can be queried by the {RS232_LOCAL_FORMAT=?} command. Any parameter can be
skippedbyusing'X'asavalue,seetheexample.
Example
 {RS232_LOCAL_FORMAT=57600;X;X;1}
 (RS232_LOCAL_FORMAT=57600;8;N;1)
Thedatabitandparitysettingshavenotbeenchanged.
section.
Value
Valuedescription
Pass-throughmode
PASS
Control mode
CONTROL
CommandInjectionmode
CI
Value
Valuedescription
4800; 7200; 9600; 14400;
19200; 38400; 57600; 115200
8; 9
N; E; O
1; 1.5; 2
Appliedfirmwarepackage:v1.3.2b3 | LDCsoftware:v2.5.7b2
HDMI-TPS-TX200series–User'sManual
6.7.3. Serial Port Format Setting (Link port)
ThiscommandsetstheformatofthelinkRS-232port(TPSport).
Command and Response
 {RS232_LINK_FORMAT=<baud_rate>;<data_bit>;<parity>;<stop_bit>}
 (RS232_LINK_FORMAT=<baud_rate>;<data_bit>;<parity>;<stop_bit>)CrLf
Parameters
Seetheprevioussection.
Example
 {RS232_LINK_FORMAT=38400;X;X;1}
 (RS232_LINK_FORMAT=38400;8;N;1)
Thedatabitandparitysettingshavenotbeenchanged.
6.7.4. Serial Port Protocol Setting (Local port)
Command and Response
 {RS232_LOCAL_PROT=<protocol>}
 (RS232_LOCAL_PROT=<protocol>)CrLf
Parameters
Parameter
Parameterdescription
<protocol>
The applied protocol in the
communication
Thecurrentsettingcanbequeriedbythe{RS232_LOCAL_PROT=?} command.
Example
 {RS232_LOCAL_PROT=LW2}
 (RS232_LOCAL_PROT=LW2)
6.7.5. Serial Port Protocol Setting (Link port)
ThiscommandsetsthecommunicationprotocolofthelinkRS-232port(TPSport).
Command and Response
 {RS232_LINK_PROT=<protocol>}
 (RS232_LINK_PROT=<protocol>)CrLf
Parameters
Seetheprevioussection.
Example
 {RS232_LINK_PROT=LW2}
 (RS232_LINK_PROT=LW2)
Value
Valuedescription
Lightware2Protocolisactive
LW2
Lightware3Protocolisactive
LW3