Wireless ZEM input Addressing:
Wireless ZEM
ZEM32-WE
Wireless ZEM Header Addressing:
Wireless ZEM
ZEM32-WE

3.11 Connecting an Output Expander

1 x Remote Output Expander can be connected to the Enforcer. Each output expander allows 16
additional outputs.
NOTE: The above shows the I/O board connected to a EURO-OEM8R8T. If using a EURO-
OEM16R+PSU, the D2+ MUST NOT be connected.
Enforcer: Installation Manual
Address
ZEM Address 0
ZEM Address 1
ZEM Address 2
ZEM Address 3
Address
ZEM Address 0
ZEM Address 1
ZEM Address 2
ZEM Address 3
Page: 13
Inputs
35-42
43-50
51-58
59-66
0-3
4-7
8-11
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF