Operation
[+]
Use the
key to add a new line:
hh:mm
Touch the
the duration of the process step (setting range 00:01 to 99:9).
mbar
Touch the
process step (setting range 1 – 1,400 mbar).
rpm
Touch the
field in the new line and set the rotation speed for the process step
(setting range 10 – 280 rpm).
°C
Touch the
field in the new line and set the heating bath temperature for the
process step (setting range 20 – 210 °C).
For each individual value in the list (vacuum pressure [
rotation speed [
be individually determined whether the setpoint should be reached
abruptly or gradually linearly.
Touch the symbol assigned to toggle between the two options:
Option abruptly:
Option gradually linear:
[+]
Use the
key to add additional lines if necessary and set the parameters for
each process step as described.
To delete a line, highlight it and touch the
After entering all required lines and values, open the on-screen keyboard by
Save
touching the
Assign an individual designation to the ramp profile.
It is not possible to assign designations for ramp profiles twice
in the system. If a desired designation already exists, a warning
message appears on the display.
In this case, change the designation or overwrite the existing ramp
profile. This operation cannot be undone!
Confirm the new designation to store the ramp profile in the system.
Switch to screen 5 in
process-end-parameters. Options:
Stop vacuum
two options)
Hysteresis
selection menu, see also section "Menu item Hysteresis Δp" on page 113)
Stop rotation
between the two options)
Stop heating bath
between the two options)
Boot lift
options)
field in the new line and use the on-screen keyboard to specify
field in the new line and define the vacuum pressure for the
rpm
] and heating bath temperature [
button.
ramp profiles
Maintain vacuum
/
(touch the entry to open the automatic/manual hysteresis
Maintain rotation
/
Hold heating bath
/
Hold lift
/
(touch the entry to switch between the two
[-]
button.
mode to define the individual
(touch the entry to switch between the
(touch the entry to switch
(touch the entry to switch
132
mbar
],
°C
]), it can

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Hei-vap expert controlHei-vap ultimateHei-vap ultimate control517-61000-00573-00000-00574-00000-00 ... Show all

Table of Contents