System Maintenance; General; Iris™ Sensor Cleaning; Iris™ Sensor Alignment (Quarterly Or As Required) - Halton M.A.R.V.E.L. Operator's Manual

Model-based automated regulation of ventilation exhaust levels
Table of Contents

Advertisement

M.A.R.V.E.L. System Maintenance

General

NOTE: A preventive maintenance program is an important aspect of an effective safety program.
Consult your manufacturing or other qualifi ed consultant with question concerning changes
observed during periodic inspections and routine maintenance.
Refer to the Capture Jet
The following maintenance steps ONLY apply to the M.A.R.V.E.L. components (IRIS™ Sensor and
Temperature Sensor).
IRIS™ Sensor Cleaning
NOTE: The IRIS™ Sensor is mounted on the Capture Jet
the sensor optics from contaminants. However, periodic cleaning may be required to keep the
optics clear.
Gently clean the IRIS™ socket with isopropyl alcohol on a cotton swab (Q-tip™), as required.
Take care not to move the position of the optic; see below on how to realign the IRIS™ Sensor.
IRIS™ Sensor Alignment (Quarterly or as required)
To align the IRIS™ Sensor, follow these steps:
1. Insert the CE Laser Alignment Tool into the socket at the bottom of the IRIS™ sensor.
2. Press the laser button, located on the side of the CE Laser Alignment Tool .
3. Gently move the IRIS™ sensor to position the laser beam point at the center of the
cooking surface. NOTE: The actual fi eld of view for most applications will be 60
degrees.
4. Remove the CE Laser Alignment Tool.
M.A.R.V.E.L. Installation Operation & Maintenance Manual
®
Hood IO&M Manual for complete details on maintaining the hoods.
®
plenum door to allow an air jet to protect
Insert into IRIS optic
Press to turn on laser
18