External Alarms Port; Table 22: Console Port Pinouts-Db9 Male - Alcatel-Lucent 7705 Installation Manual

Service aggregation router
Hide thumbs Also See for 7705:
Table of Contents

Advertisement

Appendix B: Pinout Assignments
Console Port Pinouts
Table 22
mode.

External Alarms Port

The External Alarms port provides access to three pairs of alarm output contacts and four
alarm inputs. All alarm interfaces are rated for 5 VDC and 100 mA (source or sink). Each
alarm input has a fixed severity associated with it
Major alarm inputs, and one Minor alarm input (see
are debounced for 2 seconds.
The port uses a DB15 female connector. You must provide an appropriate cable configured
according to your alarm panel.
You can display the status of the alarm inputs using the
CLI command.
Page 110
displays the Console port pin assignments. The Console port is configured for DTE
Table 22: Console Port Pinouts—DB9 Male
Pin
Signal
1
DCD
2
RXD
3
TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI
Direction
Description
Input
Data carrier detect
Input
Receive data
Output
Transmit data
Output
Data terminal ready
Signal ground
Signal ground
Input
Data set ready
Output
Request to send
Input
Clear to send
Input
Ring indicator
there is one Critical alarm input, two
Table
7705 SAR-F Installation Guide
23). State transitions on the inputs
show>chassis>environment