7705 SAR-F Overview
The
The fan speed can be one of the following:
An example of the Fan Information portion of the
Notes on 7705 SAR-F and 7705 SAR-8
The 7705 SAR-F and the 7705 SAR-8 run the same operating system software. The main
difference between the products is their hardware configuration. The 7705 SAR-8 has an
8-slot chassis that supports two CSMs, six adapter cards, and a Fan module. The
7705 SAR-F chassis has a fixed hardware configuration, replacing the 7705 SAR-8 physical
components (the CSM, Fan module, and adapter cards) with an all-in-one unit that provides
comparable functional blocks, as detailed in
The fixed configuration of the 7705 SAR-F means that provisioning the router at the "card
slot" and "type" levels is preset and is not user-configurable. Operators begin configurations
at the port level.
Note: Unless stated otherwise, references to the terms "Adapter card" and "CSM"
throughout the 7705 SAR OS documentation set include the equivalent functional blocks on
the 7705 SAR-F.
Page 44
CLI command displays the fan status as one of the following:
show chassis
•
up – all fans are operating
•
minor failure – one fan has failed
•
critical failure – two or more fans have failed
•
full speed – all fans are on
•
off – all fans are off
Fan Information
# of on-board fans
Status
Speed
show chassis
: 5
: up
: full speed
Table
3.
7705 SAR-F Installation Guide
display is shown below: