7

Appendices

7-1.

List of setting values

* Default value
* Protection
* NOVRAM
* Reference
■ System setting (settings tab)
Item
Setting value name
number
1
Moving average filter (torque)
2
Digital low-pass filter
Moving average filter
3
(rotation speed)
■ Calibration setting (calibration tab)
Item
Setting value name
number
Chapter
7
Calibration function selection1
1
Unit (torque)
Calibration function selection1
2
Min. scale division (torque)
Calibration function selection2
3
Pulse rate (rotation speed)
Calibration function selection2
4
Min. scale division
(rotation speed)
Rotation stop settings
5
Minimum input rotation speed
Rotation stop settings
6
Rotation stop mode
Calibration function selection2
7
Unit (power)
Calibration function selection2
8
Decimal place (power)
Calibration function selection2
9
Min. scale division (power)
44
44
Factory default value
◎: System setting protection
●: Calibration setting protection
◎: Saving on NOVRAM
Reference page number for each item description
Setting value range
0 (OFF), 2 to 300 [times]
3, 30, 300, Off [Hz]
0 (OFF), 2 to 300 [times]
Setting value range
mNm, Ncm, Nm, kNm,
kgm (kgfm), kgcm (kgfcm),
gcm (gfcm)
1, 2, 5, 10, 20, 50, 100
1 pulse, 4 pulses
1, 2, 5, 10
Pulse rate: 4 pulses
15rpm, 10rpm, 5rpm,
3rpm, 2rpm
Pulse rate: 1 pulse
60rpm, 40rpm, 20rpm,
12rpm, 8rpm
OFF, 2 times, 4 times, 8 times
mW, W, kW, PS, HP
99999, 9999.9,
999.99, 99.999
1, 2, 5, 10
Default
NOV
Protection
value
RAM
30
300
30
Default
NOV
Protection
value
RAM
Nm
1
4 pulses
1
15rpm
OFF
W
99999
1
Reference
P39
P40
P39
Reference
P30
P30
P34
P34
P35
P36
P34
P34
P34