Fibre-Optic Port (Optional) - Bartec POLARIS B7-72V1 Series User Manual

Panel pc professional 10.4" / 12.1" / 12.1" w
Hide thumbs Also See for POLARIS B7-72V1 Series:
Table of Contents

Advertisement

Commissioning
6.9
Fibre-Optic Port (optional 12,1")
EN 40/65
POLARIS
PROFESSIONAL- for Zone 2/22
POLARIS Panel PC Professional 10,4" / 12,1" / 12,1" W
For the fibre-optic transmission a fibre-optic converter is used inside the POLARIS and it
converts the Ethernet/IP to fibre-optic signals (Ethernet/IP Ex e connection is not required).
For transmission a converter of the same type is needed for the non-hazardous area. This
is included in the scope of supply.
Technical Data
Connection of the POLARIS
External fibre-optic converter
Power supply
Data rate
Permissible ambient temperatures
Storage/transport
Operation
Multi-mode
Range
Fibre type
Min. transmitting power
Min. sensitivity
Wave length
Plug connector
Single-mode
Range
Fibre type
Min. transmitting power
Min. sensitivity
Wave length
Plug connector
The POLARIS fibre-optic connection is approved for save mounting. The following
must be observed when installing.
DANGER
There is a risk of fatal injury in an explosive atmosphere!
Protect the ST sockets from impact effects.
Make sure the plug on the fibre-optic cable is connected or closed before you put
the POLARIS into operation.
The fibre optic cable must laid with protection. (e.g. robust cabling, protective tubes
or cable channel)
ST connector
Connection of the ST connector/RJ 45
plug
external power pack
100 MBit/s
-20 °C bis +60 °C
0 °C bis +55 °C
up to 2 km
62.5/125 µm or 50/125 µm
19 dBm
31 dBm
1310 m
ST (MS400161)
up to 15 km
9/125 µm
15 dBm
31 dBm
1310 m
ST (MS400163)
Technical data subject to change.