POLARIS BASIC
- for Zone 1 / 21
POLARIS Panel PCs 5.7" / 10.4" / 12.1"
Technical data subject to change.
09/2020
Configuration USB
Terminal Interface
X17 - X22 not connected
X23
USB
X24
USB
X25
USB
X26
USB
The individual conductors are colour-coded in a 4-wire USB cable as follows:
Panel PC
USB connection
X23
1
X26
4
X25
3
X24
2
The maximum length of a lead should not exceed 2 m.
Maximum current: 300 mA.
When configuration the HMI (Outside the Ex area) it is recommended to use an external
USB HUB (USB 2.0) to work.
Configuration RS422/USB
Terminal Interface
X17 - X18 not connected
X19
COM 1
X20
COM 1
X21
COM 1
X22
COM 1
X23
USB
X24
USB
X25
USB
X26
USB
6.6.10
Signal
VCC
+5 V
Data-
USB data signal
Data+
USB data signal
GND
Colour
RD
BK
GN
WH
6.6.11
Interface RS422/USB (optional)
Signal
TxD B (TxD+)
Transmission cable
TxD A (TxD-)
Transmission cable
RxD B (RxD+)
Receiving cable
RxD A (RxD-)
Receiving cable
VCC
+5 V
Data-
USB data signal
Data+
USB data signal
GND
Commissioning
USB interface (optional)
Function
VCC (+5 V)
GND
+ Data
- Data
Input
Input
Input
Input
EN 37/65