Technical data subject to change.
09/2020
In order to guarantee the IP degree of enclosure protection = IP54 for installation in 3G
enclosures of protection (e.g. control equipment), and = IP6X for installation in 3D
enclosures in areas where combustible dusts exist - with "protection through the enclosure"
type of protection - the reinforcement frame should be used for fastening on the front side.
A reinforcement frame is inserted between the retaining brackets and the enclosure material
for good transmission of the clamping force. This ensures even transmission of force.
For POLARIS built into the enclosure door:
The open door must be supported and secured during the installation and servicing
phase. Otherwise the wall thickness specified may lead to the door sagging slightly when
open.
DANGER
If there is no reinforcement frame, it will not be possible to maintain the
IP protection. There is a risk of fatal injury in an explosive atmosphere!
Only use enclosure with at least 2 mm wall thickness.
Insert the reinforcement frame between the holder and the enclosure.
Reinforcement frame for maintenance of Protection Class IP65
POLARIS 10.4" / 12.1" W
POLARIS 12.1"
Fit the reinforcement frame
Illustration 7: Minimum installation depth and mounting reinforcement frame