6.

MAINTENANCE

It is essential that operation and maintenance in explosion hazard areas are only carried out by
trained specialist personnel authorised to do so by the system operator.
For maintenance and repair work in explosion hazard areas, the standards EN60079-17 or
IEC60079-17, EN60079-19 or IEC60079-19 and the relevant national regulations must be
applied.
In the U.S. maintenance and inspection must be carried out in accordance with ANSI / ISA
RP12.6.01-2003 and the NEC.
In Canada maintenance and inspection must be carried out in accordance with CEC
6.1

Filter replacement

The protective filter should be cleaned or replaced periodically, in particular whenever
it has been noted that the response time has become longer.
When replacing a filter, ensure that the sensor is NOT touching the metallic filter cap!
6.2

Cleaning

6.2.1 Cleaning the display

To clean the display screen, use a damp cloth to avoid static.

6.2.2 Cleaning the sensor

Thanks to the very robust design of the sensor element, any cleaning required is very easy to
carry out. This can be carried out using suitable chemicals such as isopropyl alcohol (normal
industrial product). After cleaning in isopropyl alcohol, dip the sensor element in water and
allow to dry. The cleaning time should not be more than 2 mins. To avoid damaging the sensor
layer, the use of mechanical equipment is not permitted!
When screwing on the filter cap, ensure that the sensor is NOT touching the metallic filter cap!
6.3

Customer adjustment of humidity and temperature

See manual EE-PCS (product configuration software)
6.4

Ordering information for accessories

Designation
Stainless steel sinter filter
PTFE filter
Filter for moisture measurement in oil
Stainless steel lattice filter
Ball valve ISO 1/2" interior thread with ATEX approval
Configuration adapter for connection to the PC
Connection cable with protective circuit
between EE300Ex and configuration adapter
Blanking plate for lower housing part
Protective barrier STAHL 9002/13-280-093-001
Intrinsically safe 1-channel power supply device STAHL 9160/13-11-11
Intrinsically safe 2-channel power supply device STAHL 9160/23-11-11
Sealing plug for unused cable screw connection
Mounting flange 12mm
Mounting flange 6mm
(0.24")
1/2" ISO screw connection
1/2" NPT screw connection 12mm
1/2" welded connection
1/2" ISO screw connection
1/2" NPT screw connection 6mm
O-ring for sliding fitting
sensor retraction tool 250 bar
sensor retraction tool 40 bar
(0.24")
12mm
(0.24")
(0.24")
12mm
(0.5")
6mm
(0.24")
(0.24")
26
Order code
HA010103EX
HA010105
HA010110
HA010109
HA011403
EE-PCA
HA011061
HA011401
HA011410
HA011405
HA011406
HA011402
HA010201
HA010207
HA011102
HA011103
HA011109
HA011104
HA011105
HA050308
ZM-WA-025-040-EST
BG-WA-103-045-EST

Advertisement

Table of Contents
loading

Table of Contents