Kemppi A5 MIG Rail System 2500 Operating Manual page 12

Table of Contents

Advertisement

Delay Car
A
CH off
Delay Car: 600 ms
Set the start delay (the time that the carriage stands still
after welding has started):
1.
Use + and – buttons to change the time.
2.
Range: 100–3000 milliseconds
3.
Press MENU to continue
Value CH2-CH5
A
CH on
Value CH2: 4
Fine adjust the signal level of the memory channels at
the welding carriage for channels 2 to 5.
• Use + and – buttons to change the value.
You need to change these settings only if there is a
conflict between the memory channels set by the wire
feeder and the welding carriage.
12
© Kemppi Oy 2021
Adj0 WF
A
Adj. 0
With this parameter you can fine-tune the signal zero
level for setting the wire feed speed value.
• Use + and – buttons to change the value.
In normal use, you never need to change the value
of this parameter.
Adj0 V
With this parameter you can fine-tune the signal zero
level for setting the voltage value.
• Use + and – buttons to change the value.
In normal use, you never need to change the value
of this parameter.
A5 MIG Rail System
CH on
WF: 5
R01