Gate-Control Function; Inquiry Of Indoor Temperature With One Button; Error Display - Gree XK86 Owner's Manual

Wired controller
Table of Contents

Advertisement

6.12 Gate-control Function

When there is Gate-control System, user can insert a card to turn on the unit or
pull off a card to turn off the unit. When the card is re-inserted, the unit will recover the
operation as state in memory. When the card is pulled off (or improperly inserted),
"
" icon will show, neither remote control nor operation of wired controller will be
effective and icon "
NOTE: This model cannot be connected with gate control system on its own
because it cannot detect gate control signal directly. To realize gate control display
and gate control function, it has to be used with wired controller that includes gate
control signal detecting function (used as master and salve wired controller).

6.13 Inquiry of Indoor Temperature with One Button

In the homepage, after pressing and holding "Menu" button for 5 seconds, the
wired controller will display the indoor environment temperature for 5 seconds. Within
the 5 seconds, it can quit displaying the indoor temperature immediately and be
responded to the instructions as usual after pressing any buttons.

7 Error Display

If malfunction occurs when system is running, wired controller will display error
icon "
", error code and project number of the corresponding indoor unit. If multiple
malfunctions occur at the same time, error codes will be displayed circularly.
" will be flickering.
Wired Controller (XK86 and XE76-33/H)
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xe76-33/h

Table of Contents