Gree XK86 Owner's Manual page 34

Wired controller
Table of Contents

Advertisement

Setting
Setting scope
Cooling Temp
16°C ~30°C
of Fresh Air
(61°F~86°F)
IDU*
Heating Temp
16°C ~30°C
of Fresh Air
(61°F~86°F)
IDU*
Relative
Humidity of
65%~85%
Auto Dry*
Relative
Humidity of
65%~85%
Absence*
Temp of
5~10°C
Absence
(41°F~50°F)
Mode*
Resume After
Yes, No
Inserting Card
PM2.5 Filter*
On, Off
Time Setting
for IDU Cold
Air Prevention
Default
18°C (64°F)
22°C (72°F)
75%
75%
8°C (46°F)
Yes
Off
180s
300s
180s
420s
600s
Wired Controller (XK86 and XE76-33/H)
Only applicable to fresh air indoor units.
Only applicable to fresh air indoor units.
Only applicable to temperature-humidity
dual-control duct type indoor unit
Only applicable to temperature-humidity
dual-control duct type indoor unit
Only applicable to temperature-humidity
dual-control duct type indoor unit
When it is set as "No", it will keep the status after
inserting the gate control card, that is, if it is OFF
status when pulling out the card, when inserting
the card, it is still OFF status.
When it is set as "On", PM2.5 filter function is
activated.
Cold air prevention time is the max waiting time
from the time turning on the heating mode to the
time blowing out the hot wind. The actual waiting
time is related to the outdoor ambient
temperature. If there is cold air after turning on
the heating mode in the actual operation, please
consult the professional person to adjust this
parameter.