During Recording

Probe is disconnected

The display shows
temperature probe is disconnected. This function is useful if the probe is permanently
mounted, but you wish to take the UTREL30-16 to a computer for downloading its data.
Any values recorded during this time will not be
taken into account when calculating statistics values
or alarms.
If, for example, the temperature was above -70 °C for
12 hours (which would normally trigger an alarm
event), but the probe was disconnected for 3 hours
during this time, no alarm would be generated.
When evaluating data, any readings taken while the probe is disconnected are shown as -
-.- in the data list. The chart in LogTag
Minimum and Maximum values shown on the display will remain visible and will not be
updated until the sensor is plugged back in.
If the probe was disconnected for a complete day, the minimum and maximum statistics
for that day will show

Power Save

When
Power Save
buttons have been pressed for 30 seconds.
This function is appropriate in applications where you don't need to look at the display
frequently, such as in transit monitoring applications, as the logger uses less battery
power when the display is not turned on.
Pressing any button will re-activate the display.
Power save
is enabled or disabled when configuring the UTREL30-16 via LogTag
in the
Advanced Settings
Note: The display will turn off, even if there is a pending alarm! The Red Alert LED
will still blink.
In operation, Power Save will be active regardless of the settings made in LogTag
Analyzer.
instead of a temperature value if the logger's remote
on the display and --.- in the list.
is enabled, the display will automatically switch off if none of the
tab.
UTREL30-16 User Guide
®
Analyzer will show a gap during this period.