  • Page 1 LogTag Recorders Ltd UTRID-16 USB PDF Temperature Recorder with Display Product User Guide Document Release Version:1 Published 1 May 2016 ® Copyright © 2004-2016, LogTag Recorders GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 2: Table Of Contents

    Version Date Author Details 1 Sept 2016 Stefan Lenz Initial release. GlobalTestSupply ® www. .com Find Quality Products Online at: Page 2 of 21 UTRID-16 Product User Guide, Revision 1, copyright © 2004-2016, sales@GlobalTestSupply.com LogTag Recorders . All rights reserved.
  • Page 3: Safety Information

    ... the device is stored and operated according to LogTag Recorders ’ recommendations. Disclaimer The UTRID-16 monitors temperature exposure and not the quality of the goods it accompanies. Its purpose is to signal if product quality evaluation/testing is required. Typographical Conventions...
  • Page 4: Introduction

    /Mark inspection mark in the data listing button; can be used to stop the unit and to STOP Depending on the configuration, the UTRID-16 may produce all, some or none of /Review review data recorded during the trip. the files.
  • Page 5: Standard Configuration Options

    UTRID- GlobalTestSupply ® www. .com Find Quality Products Online at: Page 5 of 21 UTRID-16 Product User Guide, Revision 1, copyright © 2004-2016, sales@GlobalTestSupply.com LogTag Recorders . All rights reserved.
  • Page 6: Alarm Configuration Options

    8°C have occurred. conditions is triggered. Any alarm condition that is activated will be shown on the PDF, in The UTRID-16 can have up to three upper alarms, and up to three the software and on the display. lower alarms.
  • Page 7: Utrid-16 Start Options

    LogTag ® Analyzer. If you configure the UTRID-16 to start after a delay period, the recorder will not immediately record temperature readings after you have pressed , but start a countdown timer...
  • Page 8: Display Overview

    Display Overview ALERT/OK indicator MIN/MAX indicator symbol is shown as soon as the UTRID-16 has registered an The word is shown when the temperature on the display alarm event.  While there are no alarms, the symbol is shown. represents the maximum recorded temperature for the current trip.
  • Page 9: Operating The Recorder

    Operating the Recorder You will receive your UTRID-16 hibernated, i.e. in a state of low power consumption. Pressing either button will briefly show the time: The recorder cannot be started until the battery has been replaced. Please see "Appendix 1 - Battery Replacement" on page i for further details.
  • Page 10: During Recording

    ... when the most recent temperature recorded Clearing an alarm displayed ... A UTRID-16 can be configured so you can clear an alarm from the above the primary upper alarm threshold, but below the secondary display. To do this, press and hold the START/Mark button.
  • Page 11: Stopping The Utrid-16

    PAUSED Manually You can configure a UTRID-16 so it can be stopped with the STOP button. This feature is useful when you take the recorder out of a shipment and don’t want to falsify the statistics with readings taken after the shipment completion.
  • Page 12: Reviewing Alarms

    The sample screens assume you have activated the Paused functionality and have enabled the alarm review screens: GlobalTestSupply ® www. .com Find Quality Products Online at: Page 12 of 21 UTRID-16 Product User Guide, Revision 1, copyright © 2004-2016, sales@GlobalTestSupply.com LogTag Recorders . All rights reserved.
  • Page 13: Plugging The Utrid-16 Into A Usb Port

    Plugging the UTRID-16 into a USB port alarm threshold marker shown without any small alarm arrows. As soon as you plug the UTRID-16 into a USB port, the word USb appears and remains permanently on until all files have been generated.
  • Page 14: Accessing The Files

    If you have configured the UTRID-16 to generate files, these will be created every time you plug the recorder into the USB port. Once finished, USb will blink every second to indicate these files can now be accessed. a new drive or mounted device will appear. The device name will be created from the serial number of the UTRID-16.
  • Page 15: Interpreting The Data

    USB Paused Readings A gap is shown in the graph where the UTRID-16 was plugged into a compiled from information about the data it contains: USB port at the time it would otherwise have taken a reading.
  • Page 16 Shows the symbols for download marks, inspections marks and paused marks if they appear in the readings. GlobalTestSupply ® www. .com Find Quality Products Online at: Page 16 of 21 UTRID-16 Product User Guide, Revision 1, copyright © 2004-2016, sales@GlobalTestSupply.com LogTag Recorders . All rights reserved.
  • Page 17: Data Evaluation - Data List

    Make sure you remove your UTRID-16 from the USB socket when you use a date/time start, so it starts at the time you want, rather than Marked readings when unplugged from the port.
  • Page 18: Utrid-16 Factory Presets

    If a default configuration does not suit, customers can compile their own profile by specifying the parameters in the tables below when ordering. ® Please note that minimum order quantities apply for UTRID-16 recorders with profiles not stocked by LogTag Recorders .
  • Page 19 Accumulative = temperature readings are above (below) the threshold for the total time defined in the activation delay time, but may not necessarily be sequential. Only on model "M" with multiple alarms. GlobalTestSupply ® www. .com Find Quality Products Online at: Page 19 of 21 UTRID-16 Product User Guide, Revision 1, copyright © 2004-2016, sales@GlobalTestSupply.com LogTag Recorders . All rights reserved.
  • Page 20 For rules regarding setting up multiple alarms please see Alarm Configuration Options on page 6. GlobalTestSupply ® www. .com Find Quality Products Online at: Page 20 of 21 UTRID-16 Product User Guide, Revision 1, copyright © 2004-2016, sales@GlobalTestSupply.com LogTag Recorders . All rights reserved.
  • Page 21: Technical Specifications

    Includes electrostatic discharge as prescribed in EN 61000-4-2 Complies with FCC Part 15 Subparts A and B GlobalTestSupply ® www. .com Find Quality Products Online at: Page 21 of 21 UTRID-16 Product User Guide, Revision 1, copyright © 2004-2016, sales@GlobalTestSupply.com LogTag Recorders . All rights reserved.
  • Page 22: Appendix 1 - Battery Replacement

    Please recycle or dispose of the old battery according to your local environmental regulations. GlobalTestSupply ® www. .com Find Quality Products Online at: Page i of 1 UTRID-16 Product User Guide, Revision 1, copyright © 2004-2016, sales@GlobalTestSupply.com LogTag Recorders . All rights reserved.